Upright 5.6K Half Inch Fire Sprinkler | Victaulic V27
Brass Upright - Click to enlarge

Upright 5.6K Half Inch Fire Sprinkler | Victaulic V27

Your Price:$7.95
Part Number:05VUP

Choose Options

Finish
Temperature
Response
Quantity Pricing
Quantity
Price
  • 100 - 499
  • $7.55
  • 500+
  • $7.16
Part Number Temperatures Approvals / Listings
50VUP Red Bulb | 155° F (68° C)
Green Bulb | 200° F (93° C)
Blue Bulb | 286° F (141° C)
UL, ULc, FM, LPCB
Finishes Shipping Weight Wrenches
White
Chrome (special order, ships 1-2 weeks)
Brass
.17 lb / piece Open End

Product Details

Victaulic half inch 5.6K fire sprinkler uprights are standard spray models designed to produce a hemispherical spray pattern for commercial applications.

Fire sprinkler design incorporates heat sensitive frangible glass bulbs in a variety of temperatures.

The die cast fire sprinkler frame is cast with a hex-shaped wrench boss to allow easy tightening from many angles, reducing assembly effort.

Fire sprinkler is available in two responses:

Quick response 3mm bulb model V2704 or standard response 5mm bulb model V2703.

Fire sprinkler is available online in three temperatures:

155° F, 68° C (red bulb), 200° F, 93° C (green bulb), or 286° F, 141° C (blue bulb).

Fire sprinkler is available online in three finishes:

Brass, Chrome, or White.

Fire Sprinkler Listings:

UL Listed, ULc Listed, FM Approved, LPCB.


Fire Sprinkler Helpful Tips:

Tip 1: It is recommended that a qualified professional replace fire sprinklers or in any other way modify a fire sprinkler system.

Tip 2: A fire sprinkler's size describes the inner orifice diameter - either half (1/2") or three-quarter (3/4") inch. The outer diamter of a (1/2") sprinkler's threads equals three-quarters. The other diameter of a (3/4") sprinkler's threads is almost one inch.

Tip 3: Try always to match the sprinkler's response type to the one you're replacing. Replace quick response fire sprinklers with quick response fire sprinklers. Replace standard response fire sprinklers with either quick response or standard response. Equal or better!

Tip 4: Spare fire sprinkler heads and a wrench should be accessible at all times in a facility with a commercial fire sprinkler system installed. Often state regulations apply, too. Check with your local fire department.

Tip 5: Fire sprinkler systems should be visually inspected often and professionally inspected annually.

Learn more about a fire sprinkler's heat sensitive glass bulb.