Horizontal Sidewall 8.0K Three-Quarter Inch Fire Sprinkler | Victaulic V34
Victualic Horizontal Sidewall - Chrome - Click to enlarge

Horizontal Sidewall 8.0K Three-Quarter Inch Fire Sprinkler | Victaulic V34

Your Price:$20.95
Part Number:75VSW

Choose Options

Finish
Temperature
Response
Quantity Pricing
Quantity
Price
  • 100 - 400
  • $19.90
  • 500+
  • $18.86
Part No.WarrantyData SheetApprovals / Listings

75VSW

Victaulic

V34

UL, ULc, FM, LPCB


TemperaturesFinishesShipping WeightShipping Providers

Red Bulb | 155° F (68° C)
Green Bulb | 200° F (93° C)
Blue Bulb | 286° F (141° C)

White
Chrome
Brass

.17 lb / piece

UPS, USPS, Freight


Stock StatusWrenches

Not a stock item. Ships within 5-10 business days

Open End or Recessed


Product Details

Victaulic three-quarter inch 8.0K fire sprinkler horizontal sidewalls are standard spray models designed to produce a crescent shapped spray pattern for commercial applications where the sprinkler is positioned along or under a beam or ceiling.

Fire sprinkler design incorporates heat sensitive frangible glass bulbs in a variety of temperatures.

The die cast fire sprinkler frame is cast with a hex-shaped wrench boss to allow easy tightening from many angles, reducing assembly effort.

Fire sprinkler is available in two responses: Quick response 3mm bulb model V3410 or standard response 5mm bulb model V3409.

Fire sprinkler is available online in three temperatures: 155° F, 68° C (red bulb), 200° F, 93° C (green bulb), or 286° F, 141° C (blue bulb).

Fire sprinkler is available online in three finishes: Brass, Chrome, or White.

Fire Sprinkler Listings: UL Listed, ULc Listed, FM Approved, LPCB.

Fire Sprinkler Helpful Tips:

Tip 1: It is recommended that a qualified professional replace fire sprinklers or in any other way modify a fire sprinkler system.

Tip 2: A fire sprinkler's size describes the inner orifice diameter - either half (1/2") or three-quarter (3/4") inch. The outer diamter of a (1/2") sprinkler's threads equals three-quarters. The other diameter of a (3/4") sprinkler's threads is almost one inch.

Tip 3: Try always to match the sprinkler's response type to the one you're replacing. Replace quick response fire sprinklers with quick response fire sprinklers. Replace standard response fire sprinklers with either quick response or standard response. Equal or better!

Tip 4: Spare fire sprinkler heads and a wrench should be accessible at all times in a facility with a commercial fire sprinkler system installed. Often state regulations apply, too. Check with your local fire department.

Tip 5: Fire sprinkler systems should be visually inspected often and professionally inspected annually.

Learn more about a fire sprinkler's heat sensitive glass bulb.