×
888-361-6662 | Welcome, Guest Login | View Cart
Pitot Tube and Gauge Kit for Water Flow Testing
Pitot Tube and Gauge Kit

Pitot Tube and Gauge Kit for Water Flow Testing

Your Price:$139.95
Part Number:01PITU

Choose Options

Select Dial Range
N.I.S.T. Certification: Guaranteed Gauge Calibration
No
Yes [+$30.00]
Include Inspector's Choice Adjustable Hydrant/Spanner Wrench Combination
No
Yes [+$24.95]
Include 2 1/2" Brass Test Cap with 1/4" Threaded Inlet (NST)
No
Yes [+$59.95]
Quantity Pricing
Quantity
Price
  • 5 - 9
  • $130.95
  • 10+
  • $125.95
Part NumberFinishSize
01PITUNickel Plated Brass12 inch length
Kit ContentsAvailability
Hex Handle Pitot
Metal Blade
2 1/2 inch 200 PSI Gauge
Thread Seal Tape
Foam Lined Case
Usually ships within 24 hours

Product Details

The Pitot Tube and Gauge is the most accurate, efficient and economical way to measure discharge from fire hose nozzles, fire hydrants or other open orifices.

Machined from solid brass and fully nickel plated, this Fire Hydrant Pitot Tube and Gauge Kit will be your go-to tool when the job requires a water flow measurement. The intuitive design of the handle has a built-in air chamber to negate any need for an air bleeder and helps damper the gauge needle under pulsation resulting in a more accurate read.

Gauge features a quick-disconnect fitting for easy removal, faster draining of the tube, and full rotation for easy viewing.

The kit features an 8 inch (20.3 centimeters) hex handle with a 4" (10.16 centimeters) standard metal blade, 2 1/2 inch (6.35 centimeter) liquid filled gauge 1% accuracy in the mid-range, a roll of Thread Seal Tape, and a well-designed foam-lined carrying case with room for two gauges.

Not the right Pitot Gauge kit? Click the link to see all our Pitot Gauges.

NEW! Now choose any of the following eight gauge ranges for FREE!

Dial RangesMajor #'d GraduationsMinor GraduationsSmallest Graduations
0-60 psi
0-100 psi
30-0-100 psi
0-160 psi
0-200 psi
30-0-200 psi
0-300 psi
30-0-300 psi
10
10
10
20
20
20
50
50
5
-
-
10
10
10
10
10
1
2
2
2
2
2
5
5

More information:

Pitot Gauge Theoretical Discharge Conversion Table <--Note: Conversion accuracy is dependent on an accurate measurement of outlet size and the nozzle or outlet coefficient. 

How to use a Pitot Gauge to Measure Fire Hydrant Flow

5 Stars
Risk Consultant
Excellent quality good, adequate packaging and delivery within the terms.
Did you find this helpful?  2 of 3 Found Helpful
Reviewed by:  from Italy. on 11/9/2016
5/5
5 Stars
Designer/project manager
Great pitot. Sturdy construction and QRFS was best price I could find on pitot gauges of similar quality.
Did you find this helpful?  1 of 1 Found Helpful
Reviewed by:  from Salem, Virginia. on 12/22/2017
5/5

Related Items

Recently Viewed Items