Victaulic V33 Fire Sprinkler Cover Plate
Victaulic V33 Off White Fire Sprinkler Cover Plate with 135F (57C) activation temperature. This fire sprinkler cover works with Victaulic’s V33 concealed pendent fire sprinklers. The V33 cover facilitates timely activation of the V33 concealed fire sprinkler heads with a temperature rating of 135F (57C). This sprinkler cover has an outer diameter of 3-1/4 in. (83 mm).
The Victaulic V33 cover plate is perfect for building owners who are considering aesthetics with their fire sprinkler installation; the V38 cover is available in 4 different finishes without incurring additional fees. These finishes include Chrome Plated, Off White Painted, Bright White Painted, and Flat Black Painted. Along with these base finishes, for an additional fee Victaulic will custom paint this cover in any finish you prefer, so long as the paint is from Benjamin Moore or Sherwin-Williams. Contact QRFS customer support for more details.
Victaulic V33 Fire Sprinkler Cover Plate Sprinkler Head Compatibility and Listings
This Sprinkler Head Cover Plate from Victaulic is UL Listed, and/or may be listed/approved by other organizations depending on the sprinkler. It meets the requirements of a sprinkler assembly per NFPA 13, where approved by the local Authority Having Jurisdiction. It installs by simply pushing the cover into the sprinkler’s frame.
To remove your existing cover plate, gently twist the cover to the left while applying downward pressure by pulling gently as you turn.
When this Off White fire sprinkler cover plate reaches its specified temperature of 135F (57C), the solder holding the plate's decorative exterior on the frame melts, and the two separate. For many cover plates, the rated temperature is at least 20F (6.7C) cooler than the sprinkler head's activation temperature, which ensures that the cover plate detaches early enough to allow the sprinkler to activate on time. However, each manufacturer's product line varies slightly, and cover plate temperatures may be closer to or further away from the fire sprinkler's activation temperature. Use only the cover plate approved by the manufacturer for your specific sprinkler.
Victaulic V33 Cover Plate Finishes, Temperatures, and Listed Accessories
This Victaulic V33 fire sprinkler cap is available in Chrome Plated, Off White Painted, Bright White Painted, and Flat Black Painted. It is available in two temperatures at 135F (57C). You can choose from all the available options be selecting from the dropdown at the top of the page.
This Victaulic V33 Concealed sprinkler head cover is installed easily by hand. Find all related products in the Frequently Bought Together section above.
This Sprinkler Cover Plate fits the following Victaulic concealed sprinkler heads:
- V3102
- V3104
- V3301
- V3302
- V3303
- V3304
- V3517
- V3518
QRFS SKU: |
11-V-V33-FF135 |
Manufacturer Part Number: |
S3306A0040 |
Manufacturer: |
Victaulic |
Model: |
V33 |
Installation Type: |
Push On |
Adjustment: |
1/2 in. |
Outer Diameter: |
3-1/4 in. |
Inner Diameter: |
2-3/8 in |
Finish: |
Off White |
Finish Detail: |
Off White |
Temperature: |
135F |
Corrosion Resistant: |
No |
UL Listed: |
Yes |
FM Approved: |
No |
Length: |
3.25 in. (82.55 mm) |
Width: |
3.25 in. (82.55 mm) |
Height: |
3.03 in. (76.96 mm) |
Available Box/Pack Quantity: |
50 |