QRFS.com is open and fulfilling orders. Read our Emergency Preparedness Guide.

1 1/2" (38.1 mm) CPVC 90-Degree Slip x Slip Elbow

SKU
TCPVC9E5
1 1/2" CPVC 90-Degree Slip x Slip Elbow changes the direction of flow in NFPA 13, NFPA 13D, and NFPA 13R fire sprinkler systems. This UL-listed and FM-approved fitting is made with heat-resistant thermoplastic CPVC. Made in the USA!
$3.75
SKUNominal DiameterDesignMaterial
TCPVC9E51 1/2" (38.1 mm)90-Degree Slip x Slip ElbowChlorinated Polyvinyl Chloride (CPVC)
Working PressureTemperature RangeListingsThermafit Industries Part Number
175 PSI at 150F (65C)35F to 150F (2C to 65C)UL-Listed and FM-Approved. UL listed for Light Hazard Occupancies (NFPA 13) and Residential & Home Fire Sprinkler Systems (NFPA 13D, NFPA 13R)CP90-112
Availability
Usually Ships Within 48 Hours

Product Description

1 1/2" CPVC 90-Degree Slip x Slip Elbow is a corrosion-resistant CPVC thermoplastic fitting for use with fire sprinkler pipe. This 90-degree CPVC elbow features two 1 1/2" (38.1 mm) female socket connections used to redirect flow.

Each 1 1/2" CPVC 90-Degree Slip x Slip Elbow is made in the USA by Thermafit Industries, Inc., a California-based manufacturer of plumbing and fire sprinkler pipe fittings. This elbow has a working pressure rating of 175 PSI at 150F (65C) and is suitable for installation in NFPA 13, NFPA 13D, and NFPA 13R systems where allowed by state and local law.

1 1/2" CPVC 90-Degree Slip x Slip Elbow is intended for use in light hazard NFPA 13 occupancies, residential NFPA 13R occupancies, and home fire sprinkler systems in accordance with NFPA 13D. This product is UL-listed for use in wet-pipe automatic fire sprinkler systems in combination with UL-listed CPVC products.

1 1/2" CPVC 90-Degree Slip x Slip Elbow is backed by Thermafit's ten-year warranty from the date of shipment. To find Thermafit-approved CPVC glue, click here. Consult Thermafit's installation manual for minimum curing times, a full list of compatible adhesives, and friction loss allowances. Not suitable for outdoor installation.

Dimensions

CPVC Elbow Dimensions

  • A: 1.912"
  • B: 1.894"
  • C: 1.094" (Schedule 40) or 1.375" (Schedule 80)
  • G: 1.1951"
  • H: 2.5699"
  • M: 2.3438"

Technical Documents

Click here to view the manual for this 1 1/2" CPVC 90-Degree Slip x Slip Elbow.

Write Your Own Review
You're reviewing:1 1/2" (38.1 mm) CPVC 90-Degree Slip x Slip Elbow
Your Rating