1 1/2" Single Jacket Fire Hose 125 PSI | 100 feet (30.48 m)
From $119.95
To $195.95
Part Number | Hose Length | Hose Size | Coupling Size |
---|---|---|---|
150SJ125L100B | 100' (30.48 m) | 1 1/2" (38.1 mm) | 1 1/2" (38.1 mm) |
Coupling Thread | Coupling Types | Optional Coating | Pressure |
---|---|---|---|
National Standard Threads (NST/NH) or National Pipe Straight Hose Threads (NPSH/IPT) | Aluminum Rocker Lug Couplings, Brass Rocker Lug Couplings, or Brass Pin Lug Couplings | Superior Fire Hose's Steadfast Coating - Eight Colors Available | 125 PSI Working, 250 PSI Tested |
Approvals | Availability |
---|---|
FM-approved | Ships directly from factory - usually 5-10 business days |
Product Description
100' (30.48 m) of 1 1/2" (38.1 mm) Single-Jacket Fire Hose quickly moves large volumes of water, making it perfect for cleaning construction sites, draining a pool or pond, or simply moving water from one place to another. This hose arrives stenciled with one-inch lettering indicating the date of manufacture and other details in accordance with NFPA 1962.
Each of these 100' (30.48 m) Single-Jacket Fire Hoses is manufactured-to-order and stamped with the manufacturing date by Superior Fire Hose, a North Carolina-based manufacturer of durable, competitively-priced fire and industrial hose. Choose from three coupling styles, two coupling thread options, and abrasion-resistant coatings in eight colors (listed below).
100' (30.48 m) of 1 1/2" (38.1 mm) Single-Jacket Fire Hose provides greater value per foot than 50 foot or 75 foot hoses and weighs less than two 50-foot hoses. Superior's jackets consist of both staple and filament polyester, combined in a seamless and defect-free weave. The single-jacket design is lighter and more flexible than double-jacket alternatives, but not preferred where frequent moving or chafing of the hose is likely. This hose is FM-approved and comes with Superior Fire Hose's ten year warranty. With great resistance to ozone, heat, and weathering, Superior's EPDM liners are extruded in their state-of-the-art facility and made to give more than double the jacket adhesion required by the National Fire Protection Association.
Fire hoses usually ship out in 5-10 days but large orders may take longer. High quantity discounts apply. Please contact us with large order inquiries so we can provide a custom quote, either by filling out our contact form or calling us at +1 (888) 361-6662.
Product Options
Choose from three coupling types for this Single-Jacket Fire Hose:
- Aluminum Rocker Lug Couplings
- Brass Rocker Lug Couplings
- Brass Pin Lug Couplings
Aluminum couplings are about one-third the weight of brass and almost twice as strong. Brass, while heavier, offers superior abrasion resistance. Pin-lug hose couplings, available only in brass, can be hand-tightened or secured with a spanner wrench, but may snag when pulled over rough surfaces. Rectangular rocker-lug couplings are beveled to help them pass over obstructions and are available in aluminum or brass.
This 125 PSI fire hose is available with two 1 1/2" (38.1 mm) coupling thread types:
- National Standard Threads (NST/NH)
- National Pipe Straight Hose Threads (NPSH/IPT)
National Standard Thread, or National Hose Thread, is the most widely-adopted thread standard in the United States. National Pipe Straight Hose is used with discharge hose, low-pressure suction applications, and in other applications for water-based systems.
An optional, abrasion-resistant Steadfast Coating is available for this 100' (30.48 m) 125 PSI Fire Hose in eight different colors:
- Red
- Orange
- Blue
- Tan
- Yellow
- Green
- Black
- Brown
- Purple
Environmentally safe, durable, and water-repellent, Superior's Steadfast Coating is specially formulated with polymers and binders that won't take away from the natural flexibility of the hose.
Sign In
Create New Account