Preparing for a fire inspection? Avoid common citations using our FREE inspection checklist.

1 3/4" Single Jacket Fire Hose 250 PSI | 75 feet (22.86 m)

SKU
175SJ250L075B
75' (22.86 m) of 1 3/4" (44.5 mm) Single-Jacket Fire Hose, suitable as a industrial & contractor hose hose, is FM-approved and comes with Superior Fire Hose's 10-year warranty. Brass & aluminum NST or NPSH couplings, a UL-listing, and eight colored abrasion-resistant coatings are available.

From $159.95

To $260.45

Customize 1 3/4" Single Jacket Fire Hose 250 PSI | 75 feet (22.86 m)
1 3/4" Single Jacket 250PSI 75 ft   + $159.95

* Required Fields

  • Buy 10 with 5% discount each
  • Buy 25 with 10% discount each
  • Buy 50 with 15% discount each
  • Buy 100 with 15% discount each
Your Customization
1 3/4" Single Jacket Fire Hose 250 PSI | 75 feet (22.86 m)
1 3/4" Single Jacket Fire Hose 250 PSI | 75 feet (22.86 m)

In stock

Total: $159.95

Summary
    Part NumberHose LengthHose SizeCoupling Size
    175SJ250L075B75' (22.86 m)1 3/4" (44.5 mm)1 1/2" (38.1 mm) Reduced
    Coupling ThreadCoupling TypesOptional CoatingPressure
    National Standard Threads (NST/NH) or National Pipe Straight Hose Threads (NPSH/IPT)Aluminum Rocker Lug Couplings, Brass Rocker Lug Couplings, or Brass Pin Lug CouplingsSuperior Fire Hose's Steadfast Coating - Eight Colors Available250 PSI Working, 500 PSI Tested
    ApprovalsAvailability
    FM-approved, with UL-listing optionalShips directly from factory - usually 5-10 business days

    Product Description

    75' (22.86 m) of 1 3/4" (44.5 mm) Single-Jacket Fire Hose quickly moves large volumes of water, making it perfect for cleaning construction sites, draining a pool or pond, or simply moving water from one place to another. This hose arrives stenciled with one-inch lettering indicating the date of manufacture and other details in accordance with NFPA 1962.

    Each of these 75' (22.86 m) Single-Jacket Fire Hoses is manufactured-to-order and stamped with the manufacturing date by Superior Fire Hose, a North Carolina-based manufacturer of durable, competitively-priced fire and industrial hose. Choose from three coupling styles, two coupling thread options, one additional UL-listing, and abrasion-resistant coatings in eight colors (listed below).

    75' (22.86 m) of 1 3/4" (44.5 mm) Single-Jacket Fire Hose provides more length than 50-foot hose at a lower cost per foot and may be paired with another 75-foot hose for use as a high-rise bundle. Superior's jackets consist of both staple and filament polyester, combined in a seamless and defect-free weave. The single-jacket design is lighter and more flexible than double-jacket alternatives, but not preferred where frequent moving or chafing of the hose is likely. This hose is FM-approved and comes with Superior Fire Hose's ten year warranty. With great resistance to ozone, heat, and weathering, Superior's EPDM liners are extruded in their state-of-the-art facility and made to give more than double the jacket adhesion required by the National Fire Protection Association.

    Fire hoses usually ship out in 5-10 days but large orders may take longer. High quantity discounts apply. Please contact us with large order inquiries so we can provide a custom quote, either by filling out our contact form or calling us at +1 (888) 361-6662.

    Product Options

    Each Superior fire hose is Factory Mutual (FM) approved. An optional UL listing is available for this hose for applications which require a listed fire hose.

    Choose from three coupling types for this Single-Jacket Fire Hose:

    • Aluminum Rocker Lug Couplings
    • Brass Rocker Lug Couplings
    • Brass Pin Lug Couplings

    Aluminum couplings are about one-third the weight of brass and almost twice as strong. Brass, while heavier, offers superior abrasion resistance. Pin-lug hose couplings, available only in brass, can be hand-tightened or secured with a spanner wrench, but may snag when pulled over rough surfaces. Rectangular rocker-lug couplings are beveled to help them pass over obstructions and are available in aluminum or brass.

    This 250 PSI fire hose is available with two 1 1/2" (38.1 mm) reduced coupling thread types:

    • National Standard Threads (NST/NH)
    • National Pipe Straight Hose Threads (NPSH/IPT)

    National Standard Thread, or National Hose Thread, is the most widely-adopted thread standard in the United States. National Pipe Straight Hose is used with discharge hose, low-pressure suction applications, and in other applications for water-based systems.

    An optional, abrasion-resistant Steadfast Coating is available for this 75' (22.86 m) 250 PSI Fire Hose in eight different colors:

    • Red
    • Orange
    • Blue
    • Tan
    • Yellow
    • Green
    • Black
    • Brown
    • Purple

    Environmentally safe, durable, and water-repellent, Superior's Steadfast Coating is specially formulated with polymers and binders that won't take away from the natural flexibility of the hose.

    Write Your Own Review
    You're reviewing:1 3/4" Single Jacket Fire Hose 250 PSI | 75 feet (22.86 m)
    Your Rating