Need a replacement fire sprinkler system part? Our trained staff will help you find the right part, the first time. Call us at 888-361-6662.

2" Double Jacket Fire Hose 200 PSI | 75 Feet (22.86 m)

SKU
200DJ200L075B
75' (22.86 m) of 2" (50.8 mm) Double-Jacket 200 PSI Fire Hose, suitable as a contractor & industrial hose, is FM-approved and comes with Superior Fire Hose's 10-year warranty. 2" (50.8 mm) or 1 1/2" (38.1 mm) NST or NPSH couplings and eight colored abrasion-resistant coatings are available.

From $219.95

To $302.95

Customize 2" Double Jacket Fire Hose 200 PSI | 75 Feet (22.86 m)
2" Double Jacket 200PSI 75 ft   + $219.95

* Required Fields

  • Buy 10 with 5% discount each
  • Buy 25 with 10% discount each
  • Buy 50 with 15% discount each
  • Buy 100 with 15% discount each
Your Customization
2" Double Jacket Fire Hose 200 PSI | 75 Feet (22.86 m)
2" Double Jacket Fire Hose 200 PSI | 75 Feet (22.86 m)

In stock

Total: $219.95

Summary
    Part NumberHose LengthHose SizeCoupling Size
    200DJ200L075B 75' (22.86 m) 2" (50.8 mm) 2" (50.8 mm) or 1 1/2" (38.1 mm) Reduced
    Coupling ThreadCoupling TypesOptional CoatingPressure
    National Standard Threads (NST/NH) or National Pipe Straight Hose Threads (NPSH/IPT) Aluminum Rocker Lug Couplings Superior Fire Hose's Steadfast Coating - Eight Colors Available 200 PSI Working, 400 PSI Tested
    ApprovalsAvailability
    FM-approved Ships directly from factory - usually 5-10 business days

    Product Description

    75' (22.86 m) of 2" (50.8 mm) Double-Jacket 200 PSI Fire Hose quickly moves large volumes of water under high pressure, making it perfect for construction and industrial applications, including washdowns, irrigation, and filling pools. With a 2" (50.8 mm) inside diameter and a 200 PSI service pressure, this product exceeds normal requirements set out for contractor hose.

    Each of these 75' (22.86 m) Double-Jacket Fire Hoses is manufactured-to-order and stamped with the manufacturing date by Superior Fire Hose, a North Carolina-based manufacturer of durable, competitively-priced fire and industrial hose. Choose from two coupling threads in two sizes, and abrasion-resistant coatings in eight colors (listed below).

    75' (22.86 m) of 2" (50.8 mm) Double-Jacket 200 PSI Fire Hose provides more length than 50-foot hose at a lower cost per foot. Superior's jackets consist of both staple and filament polyester, combined in both warp and weft direction and distributed around the circumference for excellent pressure containment. The double-jacket design adds an extra layer of protection from burns, UV rays, chafing, and damage, extending the hose's service life and preventing catastrophic hose bursts under pressure. This hose is FM-approved and comes with Superior Fire Hose's ten year warranty. With great resistance to ozone, heat, and weathering, Superior's EPDM liners are extruded in their state-of-the-art facility and made to give more than double the jacket adhesion required by the National Fire Protection Association.

    Fire hoses usually ship out in 5-10 days but large orders may take longer. High quantity discounts apply. Please contact us with large order inquiries so we can provide a custom quote, either by filling out our contact form or calling us at +1 (888) 361-6662.

    Product Options

    One coupling type is available for this Double-Jacket Fire Hose:

    • Aluminum Rocker Lug Couplings

    Aluminum couplings are about one-third the weight of brass and almost twice as strong. These rectangular rocker-lug couplings are beveled to help them pass over obstructions.

    This 200 PSI fire hose is available with two 2" (50.8 mm) or 1 1/2" (38.1 mm) reduced coupling thread types:

    • National Standard Threads (NST/NH)
    • National Pipe Straight Hose Threads (NPSH/IPT)

    National Standard Thread, or National Hose Thread, is the most widely-adopted thread standard in the United States. National Pipe Straight Hose is used with discharge hose, low-pressure suction applications, and in other applications for water-based systems.

    An optional, abrasion-resistant Steadfast Coating is available for this 75' (22.86 m) 200 PSI Fire Hose in eight different colors:

    • Red
    • Orange
    • Blue
    • Tan
    • Yellow
    • Green
    • Black
    • Brown
    • Purple

    Environmentally safe, durable, and water-repellent, Superior's Steadfast Coating is specially formulated with polymers and binders that won't take away from the natural flexibility of the hose.

    Write Your Own Review
    You're reviewing:2" Double Jacket Fire Hose 200 PSI | 75 Feet (22.86 m)
    Your Rating