QRFS.com is open and fulfilling orders. Read our Emergency Preparedness Guide.

2" x 2" x 1" CPVC Slip Outlet-Reducing Tee

SKU
TCPVCRT663
2" x 2" x 1" CPVC Slip Outlet-Reducing Tee has a 2" run, another 2" run, and a 1" outlet. Ideal for NFPA 13, NFPA 13D, and NFPA 13R fire sprinkler systems, this UL & FM approved CPVC fitting is heat-resistant and made in the USA!
$8.60
SKUNominal DiameterRun 1 Diameter (Inside)Run 2 Diameter (Inside)
TCPVCRT6632" x 2" x 1"2"2"
Outlet Diameter (Inside)DesignMaterialWorking Pressure
1"Slip Outlet-Reducing TeeChlorinated Polyvinyl Chloride (CPVC) to Cell Class 2344-7B (ASTM D1784)175 PSI at 150F (65C)
Temperature RangeListingsThermafit Industries Part NumberAvailability
35F to 150F (2C to 65C)UL-Listed and FM-Approved. UL listed for Light Hazard Occupancies (NFPA 13) and Residential & Home Fire Sprinkler Systems (NFPA 13D, NFPA 13R)CPRT-221Usually Ships Within 48 Hours

Product Description

2" x 2" x 1" CPVC Slip Outlet-Reducing Tee is a corrosion-resistant CPVC thermoplastic fitting for use with fire sprinkler pipe. This CPVC outlet-reducing tee features three female socket connections used to split the flow of water into two directions. This tee has a 2" run, another 2" run, and a 1" outlet.

Each 2" x 2" x 1" CPVC Slip Outlet-Reducing Tee is made in the USA by Thermafit Industries, Inc., a California-based manufacturer of plumbing and fire sprinkler pipe fittings. This outlet-reducing tee has a working pressure rating of 175 PSI at 150F (65C) and is suitable for installation in NFPA 13, NFPA 13D, and NFPA 13R systems where allowed by state and local law.

2" x 2" x 1" CPVC Slip Outlet-Reducing Tee is intended for use in light hazard NFPA 13 occupancies, residential NFPA 13R occupancies, and home fire sprinkler systems in accordance with NFPA 13D. This product is UL-listed for use in wet-pipe automatic fire sprinkler systems in combination with UL-listed CPVC products.

2" x 2" x 1" CPVC Slip Outlet-Reducing Tee is backed by Thermafit's ten-year warranty from the date of shipment. To find Thermafit-approved CPVC glue, click here. Consult Thermafit's installation manual for minimum curing times, a full list of compatible adhesives, and friction loss allowances. Not suitable for outdoor installation.

Dimensions

CPVC Outlet-Reducing Tee Dimensions

  • M: 2.8438"
  • M1: 1.875"
  • M2: 2.8438"
  • L: 4.7143"
  • H: 2.3470"

Technical Documents

Click here to view the manual for this 2" x 2" x 1" CPVC Slip Outlet-Reducing Tee.

Write Your Own Review
You're reviewing:2" x 2" x 1" CPVC Slip Outlet-Reducing Tee
Your Rating