QRFS will be closed on Friday July 3rd in honor of Independence Day. We will back open on Monday July 6th.

3/4" (19.05 mm) CPVC Slip x Slip x Slip Tee

SKU
TCPVCST2
3/4" (19.05 mm) CPVC Slip x Slip x Slip Tee allows water to flow in two directions from a single source. Ideal for NFPA 13, NFPA 13D, and NFPA 13R fire sprinkler systems, this UL & FM approved CPVC fitting is heat-resistant and made in the USA!
$1.25
SKUNominal DiameterDesignMaterial
TCPVCST23/4" (19.05 mm)Slip x Slip x Slip TeeChlorinated Polyvinyl Chloride (CPVC) to Cell Class 2344-7B (ASTM D1784)
Working PressureTemperature RangeListingsThermafit Industries Part Number
175 PSI at 150F (65C)35F to 150F (2C to 65C)UL-Listed and FM-Approved. UL listed for Light Hazard Occupancies (NFPA 13) and Residential & Home Fire Sprinkler Systems (NFPA 13D, NFPA 13R)CPT-34
Availability
Usually Ships Within 48 Hours

Product Description

3/4" (19.05 mm) CPVC Slip x Slip x Slip Tee is a corrosion-resistant CPVC thermoplastic fitting for use with fire sprinkler pipe. This CPVC tee features three 3/4" (19.05 mm) female socket connections used to split the flow of water into two directions.

Each 3/4" (19.05 mm) CPVC Slip x Slip x Slip Tee is made in the USA by Thermafit Industries, Inc., a California-based manufacturer of plumbing and fire sprinkler pipe fittings. This tee has a working pressure rating of 175 PSI at 150F (65C) and is suitable for installation in NFPA 13, NFPA 13D, and NFPA 13R systems where allowed by state and local law.

3/4" (19.05 mm) CPVC Slip x Slip x Slip Tee is intended for use in light hazard NFPA 13 occupancies, residential NFPA 13R occupancies, and home fire sprinkler systems in accordance with NFPA 13D. This product is UL-listed for use in wet-pipe automatic fire sprinkler systems in combination with UL-listed CPVC products.

3/4" (19.05 mm) CPVC Slip x Slip x Slip Tee is backed by Thermafit's ten-year warranty from the date of shipment. To find Thermafit-approved CPVC glue, click here. Consult Thermafit's installation manual for minimum curing times, a full list of compatible adhesives, and friction loss allowances. Not suitable for outdoor installation.

Dimensions

CPVC Tee Dimensions

  • A: 1.058"
  • B: 1.046"
  • C: 0.719" (Schedule 40) or 1.000" (Schedule 80)
  • G: 0.6512"
  • H: 1.4559"
  • L: 2.875"
  • M: 1.3125"

Technical Documents

Click here to view the manual for this 3/4" (19.05 mm) CPVC Slip x Slip x Slip Tee.

Write Your Own Review
You're reviewing:3/4" (19.05 mm) CPVC Slip x Slip x Slip Tee
Your Rating