3/8″ (10 mm) Loos & Co. Two-Way Anchoring Fitting for Seismic Cable Bracing | Pack of 5

SKU
SAF238
Pack of 5 Loos & Co. Universal Seismic Restraint Clip attaches seismic cable bracing to fire sprinkler systems, HVAC equipment, and trapeze supports, for new installations. Each SAFR2-3/8 Model features two cable mounting holes and a fastener mount that installs to  3/8″ (10 mm) fasteners. These clips are UL-listed and proudly made in the United States in compliance with the Buy American Act.
$31.99
SKU Construction Finish
SAF238 Zinc-Plated Steel Gray
Mounting Size Compatible Bracing Cables Acceptable Fasteners
3/8″ (10mm) #GO3 (Gold), #GR6 (Green), and #OR4 (Orange) Lag Bolts, Bolts, Threaded Rod, Concrete Anchors
Breaking Strength Approvals & Listings Availability
Maintains Loos & Co. Breaking Strength of Orange (1,700 lb.), Green (4,200 lb.), or Gold (920 lb.) Cables UL Listed, IBC Code & RoHS Compliant, NFPA 13 9.3.5 Usually Ships Within 48 Hours

3/8″ Loos & Co. Two-Way Anchoring Fitting for Seismic Cable Bracing

Use this pack of five (5) two-way anchoring fitting to secure Loos & Co. seismic bracing cables to a 3/8″ (10 mm) fastener. With a 3/8″ fastener mount and two cable mounts, this fastener allows contractors to secure Loos-brand cables with ease. Simply remove the fastener, slide it right in, and replace and tighten again until firm. As part of a seismic cable bracing assembly, this fitting can help support fire sprinkler systems, cable trays, HVAC equipment, clevis hangers, and trapeze supports.

Each of these five (5) cable bracing clips is outfitted with two mounting holes that will accept Gold (#GO3), Green (#GR6), or Orange (#OR4) cable and is ideal for 2-way “cross” bracing. When applied correctly, the Loos and Co. SAF2 model will maintain the rated break strength of both compatible seismic cables without the need for a thimble and may be used at both ends of the cable for anchoring equipment.

Every 3/8″ two-way seismic anchor is UL-listed, compliant with many national and international building codes, and suitable for installation in accordance with chapter 9.3 of NFPA 13. It is also proudly made in the USA, in full compliance with the Buy American Act, and the Restriction of Hazardous Substances Directive adopted in 2004 by the European Union.

Why should my fire sprinkler system include seismic bracing?

All seismic construction for fire sprinkler systems should be designed and completed by licensed professionals. Seismic support for pipes, especially sprinkler pipes, is critical for two reasons: 1) minimizing stress in piping, and 2) minimizing damaging forces in the event of an earthquake. This is accomplished with a careful balance of flexibility and rigidity in the piping that assures the piping will move with the building, instead of a direction that could cause significant damage to the piping, the building, or its occupants. 

Will this clip work for my seismic bracing assembly?

Loos & Co. Seismic Restraint Clip is designed for use in attaching systems and equipments to a structural member using a 3/8″ (10 mm) fastener. The two mounting holes will accept Gold (#GO3), Green (#GR6), and Orange (#OR4) cables to maintain breaking strengths up to 4,200 pounds.

Browse our selection of bracing cable and anchoring components, including:

Hand tools available for Loos & Co.’s seismic bracing cable include:

Or, see our full selection of pipe-hanging and fire protection tools.

 

Write Your Own Review
You're reviewing:3/8″ (10 mm) Loos & Co. Two-Way Anchoring Fitting for Seismic Cable Bracing | Pack of 5
Your Rating