  1. #151 – Why and When the US Retrofits Sprinklers in Existing Buildings

    #151 – Why and When the US Retrofits Sprinklers in Existing Buildings
    A look at the evolution and impact of fire safety code that has caused most new commercial buildings to have fire sprinklers – and how revised code and local governments are now driving sprinkler retrofits in existing buildings.
  2. #150 – Guide to Dry Sprinkler Systems, Part 2: Components and Installation

    #150 – Guide to Dry Sprinkler Systems, Part 2: Components and Installation
    With additional control equipment and air pressurization devices not found in wet sprinkler systems, installing a dry sprinkler system ups the complexity factor. QRFS explains components and NFPA requirements for installing dry systems in areas prone to freezing.
  3. #149 – Significant Changes to the 2019 Edition of NFPA 13, Part 2

    #149 – Significant Changes to the 2019 Edition of NFPA 13, Part 2
    NFPA 13: Standard for the Installation of Sprinkler Systems has guided insurers, installers, and designers for more than a century. QRFS looks at the National Fire Protection Association's 2019 changes, exploring technical revisions impacting ESFR storage sprinklers, system components, and sprinkler system design.
  4. #148 – Fire Codes for Business: The Business Occupancy

    #148 – Fire Codes for Business: The Business Occupancy
    Follow the right fire codes for business that govern fire sprinklers, fire alarms, fire extinguishers, and safe food service operations if your organization is classified as a business occupancy.
  5. #147 – Significant Changes to the 2019 Edition of NFPA 13, Part 1

    #147 – Significant Changes to the 2019 Edition of NFPA 13, Part 1
    NFPA 13 has guided sprinkler installers and designers for more than a century. QRFS looks at NFPA 13 2019 changes, including an organizational overhaul and technical revisions impacting residential sprinklers in NFPA 13 systems.
  6. #146 – Heavy-Duty Fire Sprinkler Head Guards Protect Sprinklers from Hard Hits

    #146 – Heavy-Duty Fire Sprinkler Head Guards Protect Sprinklers from Hard Hits
    Collisions with sprinkler heads can cause costly flooding — but standard fire sprinkler cages may not be strong enough to withstand the hits some sprinklers are likely to face. QRFS looks at a line of heavy-duty fire sprinkler head guards designed to address the vulnerabilities in high-impact environments.
  7. #145 – Tyco's New LFP Antifreeze Meets NFPA Listing Requirements

    #145 – Tyco's New LFP Antifreeze Meets NFPA Listing Requirements
    As the 2022 deadline for phasing out all current antifreeze solutions in wet sprinkler systems looms, the first – and only – product to meet the National Fire Protection Association’s (NFPA) standard is good news for property owners in regions that suffer bitter winters. QRFS reveals why current solutions were deemed unsafe and details the new solution.