#66 - Ultimate Guide to Fire Extinguisher Classes: Servicing and Use
#66 - Ultimate Guide to Fire Extinguisher Classes: Servicing and Use
All portable fire extinguishers can stop small fires before they get out of hand, but each extinguisher is specially-suited to only some types of fires
Portable fire extinguishers defend homes, offices, and commercial buildings everywhere against fires. But not all fires are alike. An extinguisher that doesn’t match the type of fire or doesn’t have enough power may do nothing at all—or make things even worse.
In this article, we take a look at fire classifications and fire extinguisher classes, explaining which extinguishers are best suited to a particular type of fire. Then, we provide an overview of fire extinguisher inspection and help you better understand the basics of purchasing an extinguisher to fit your building’s needs.
Need to shop for an extinguisher now? Feel free to click here to view our selection of fire extinguishers.
How many fire classifications are there and what are they?
Fire classifications simplify the task of matching a fire extinguisher to the expected type of fire. Water, for example, performs well against fires involving wood or plastics—but it would spread fires burning grease or gasoline.
In the United States, fires belong to one of five fire classifications:
- Class A Fire: Ordinary combustibles such as wood, paper, cloth, trash, and plastics.
- Class B Fire: Flammable liquids (excluding grease and cooking oils) like gasoline, petroleum, oil, and paint. Also includes gasses, like propane and butane.
- Class C Fire: Energized electrical equipment like appliances, transformers, and motors. The electric must be turned off to aid extinguishing efforts.
- Class D Fire: Combustible metals like titanium, magnesium, aluminum, potassium, sodium, and others.
- Class K Fire: Animal and vegetable fats, cooking oils and greases, and other liquids generally used in food preparation.
In some cases, a fire may belong to two, three, or even more of these classes—in the end, a fire’s class is determined by a mix of the fire’s fuel source and other special hazards that emerge as the material burns.
How does a fire extinguisher work and how should it be used?
Any fire has at three essential elements:
- Extreme heat
- Oxygen (or another type of gas)
- Fuel—the burning material.
A fire stops burning when any one of these elements is removed. The relationship between these elements is often visualized as a “fire triangle” (pictured below). While it’s the easiest to visualize, the fire triangle has been largely replaced by the fire tetrahedron. The tetrahedron adds one more element: chain reactions, which create a gaseous fuel that sustains fires.

The “fire triangle” illustrates the elements needed for a fire to ignite. Removing any one of these three elements stops the fire from burning. Source: Wikipedia.
Some extinguishing agents smother the fire, depriving it of oxygen. Others cool the burning material and remove heat. All fire extinguishers are similar in the sense that they deprive the fire of one or more of these elements. But not all extinguishers are effective against the same fires. Some can’t penetrate deeply enough to stop fires in ordinary combustibles, while others can’t stop fires in flammable liquids—and can even spread the fire.
What are the types of fire extinguishers and their uses?
Most fire extinguishers operate in a fashion similar to an aerosol can. The tank contains compressed gas, pressurized liquid or a combination of the two with an added extinguishing agent. Squeezing the fire extinguisher’s lever creates an opening that allows the compressed material to escape through a nozzle or short hose.
But beyond those mechanical similarities, fire extinguishers vary widely. There are at least eight types of fire extinguishers:
Carbon Dioxide (CO2)
Carbon dioxide extinguishers are Class B and Class C fire extinguishers. These extinguishers remove the oxygen from the fire triangle and infuse a cold discharge to cool the fire. Unlike water or some other extinguishing agents, CO2 does not conduct electricity, making it especially well-suited for electrical fires.

CO2 fire extinguishers, like this 5-pound model from Buckeye, feature a large horn instead of a hose.
Water and Foam
These extinguishers employ foam agents to remove the heat from the flames. The foam also covers the fuel in a blanket that deprives the fire of oxygen. Water and foam extinguishers are used in Class A fires only. The water in these extinguishers can cause the flammable liquids in B to spread or increase the shock hazard in a Class C fire.
Dry Chemical
Dry chemical fire extinguishers use multipurpose agents that extinguish Class A, B and C fires. This suitability for the most common fire types makes these and other class ABC fire extinguishers the go-to choice in homes or offices.
Wet Chemical
Wet chemical extinguishers remove the fire’s heat. The chemical extinguishing agent also creates a barrier between the oxygen and the fuel. Some wet chemical extinguishers can tame both Class K and Class A fires.
Clean Agent/Halogenated
Clean agent and halogenated extinguishers deprive fires of heat. These extinguishers leave no residue, making them ideal for use in situations where other agents might damage expensive equipment. Most of these extinguishers belong to fire extinguisher class BC. However, some larger clean agent extinguishers can also fight Class A fires. These extinguishers provide an environmentally-friendly alternative to Halon extinguishers, which release ozone-damaging chemicals.
Dry Powder
Like dry chemical extinguishers, dry powder extinguishers deprive the fire of oxygen or remove the fire’s heat. These belong to fire extinguisher class D, making them suitable for use only with combustible metal fires.
Water Mist
Water Mist extinguishers remove the fire’s heat. Some fight only Class A fires while others, surprisingly, can tackle Class C electrical fires. By breaking water into fine droplets, many of these extinguishers can cleanly extinguish electrical fires without allowing electricity to travel through the spray. Water mist extinguishers can serve as an alternative to clean agent extinguishers.

A water mist extinguisher. Source: Buckeye Fire.
Cartridge Operated Dry Chemical
This multipurpose dry chemical extinguisher works for Class A, B, and C fires. Cartridge-operated dry chemical extinguishers work for Class A fires by creating a barrier between the oxygen and fuel elements.
UL classifications make it easy to choose the right fire extinguisher for a building’s hazards
UL—formerly Underwriter’s Laboratories—establishes widely-used standards for fire extinguisher manufacturers. As part of these standards, extinguishers are labeled with UL classification ratings used to determine which kinds of fires it can effectively fight.

This extinguisher’s classification reads 4A:80B:C, indicating suitability for use against Class A, B, and C fires.
The letters in these ratings indicate the fire extinguisher’s class. A 2A:10B:C fire extinguisher, for example, can be used on Class A, B, and C fires. The numbers preceding each of these letters indicate how effective the fire extinguisher is at extinguishing that particular type of fire.
For each A, that extinguisher’s agent delivers the extinguishing equivalent of 1.25 gallons of water. 8A extinguishers, then, are as powerful against ordinary combustibles as 10 gallons of water (8 x 1.25 = 10). The B:C rating represents square footage—a well-handled 10B:C extinguisher can stop 10 square feet worth of both B and C fires. The “C” is omitted for extinguishers not suitable for use on electrical equipment.
Some extinguishers also include a “K” rating, indicating suitability for use against hot cooking oils and greases. However, “K” extinguishers do not include a water equivalent or square footage rating. Notably, UL does not provide a numerical rating for Class D fires. Instead, the manufacturer indicates the extinguisher’s suitability against specific metal fires elsewhere on the label.
Regular fire extinguisher inspection and servicing required
According to OSHA, the Occupational Safety and Health Administration, fire extinguishers used in the workplace must be visually inspected on a monthly basis. This mandate parallels guidelines from the National Fire Protection Association (NFPA) that require building owners to verify, at intervals not exceeding 31 days, that fire extinguishers are properly pressurized, easily accessed, and in good condition.
During a monthly fire extinguisher inspection, all extinguishers must be in their designated place and visibly marked. Inspectors should weigh or lift each extinguisher to ensure that it has plenty of extinguishing agent available. Finally, the person inspecting the extinguishers should document, sign, and date the results. All fire extinguishers should list the year and month of the last inspection and the extinguisher’s expiration date on a tag.
All fire extinguishers should have more thorough inspection and maintenance on an annual basis. Extinguishers should undergo a complete visual examination, checking for damage, corrosion, dents, and wear. Hoses must also be checked for blockage and use and replaced if the inspection turns up evidence that the fire extinguisher has been used.

Regular inspection can identify problems like these before a fire extinguisher fails. Source: iCreatables.
These inspections should also determine if a fire extinguisher requires a hydrostatic test. Hydrostatic tests pressurize an extinguisher to determine if the tank has weakened. Because a weakened fire extinguisher poses the threat of failure or explosion upon use, extinguishers that fail hydrostatic tests may not return to service. The frequency of required hydrostatic tests varies with the extinguisher’s type, but dry chemical ABC extinguishers—the most common type—must undergo testing at least every 12 years.
What to look for when buying a fire extinguisher online
Here are a few tips that can make it easier to put all this information together and buy a fire extinguisher online:
- Check to make sure the extinguisher meets your building’s requirements. If you are unsure, check with the authority having jurisdiction (AHJ)—typically, your local fire marshall.
- Select the extinguisher type and size to suit the needs and hazards of the room or building. Remember, class ABC fire extinguishers can combat a broad range of fires in combustibles, flammable liquids, and electrical fires. For a closer look at the standards governing extinguisher placement, see our guide to when and where fire extinguishers should be installed.
- Ensure that every extinguisher you purchase is fully charged.
- Because fire extinguishers are considered hazardous materials by the Department of Transportation (DOT), they must be labeled or marked appropriately to ensure their safe transportation from one location to another.
Purchase or replace your fire extinguisher with QRFS
If you need a new fire extinguisher, take a look at our selection of CO2 and dry chemical ABC extinguishers. We ship from locations all over the United States, which means we can get your new extinguisher to you fast!
All extinguishers come fully charged and operable. You can select a FREE wall bracket or upgrade to a vehicle mounting bracket right on the product page before adding the item to your cart.
To get started, click on one of the ABC or CO2 extinguishers pictured in the table below or click here to view our full selection of fire extinguishers.
We have access to almost any fire extinguisher you could need, including wheeled on/offshore models, dry chemical, halotron, mist and foam systems, nitrogen-operated and dry-powder models, and more. If you’re looking for an extinguisher that isn’t listed on this page, call us at +1 (888) 361-6662 or email support@qrfs.com.
ABC Dry Chemical Fire Extinguishers
With a spray distance ranging from 9-21 feet (varies by size), and models from 2.5 to 20 lbs, these completely rechargeable, these corrosion-resistant dry chemical extinguishers will exceed your expectations year over year. You can view our entire selection of dry chemical ABC fire extinguishers by clicking here.
Type | Description |
![]() 2.5 lb ABC Dry Chemical Extinguisher 1A:10B:C – ANSI/UL |
|
![]() 5 lb ABC Dry Chemical Extinguisher 3A:40B:C – ANSI/UL |
|
![]() 10 lb ABC Dry Chemical Extinguisher 4A:80B:C – ANSI/UL |
|
![]() 20 lb ABC Dry Chemical Extinguisher 10A:120B:C – ANSI/UL |
|
CO2 Fire Extinguishers
With a range of 4-8 feet and high-performing discharge valves, the CO2 extinguishers from QRFS will meet your specific requirements every time. View our selection of CO2 extinguishers here.
Type | Description |
![]() 5 lb CO2 Extinguisher 5B:C – ANSI/UL |
|
![]() 10 lb CO2 Extinguisher 10B:C – ANSI/UL |
|
![]() 15 lb CO2 Extinguisher 10B:C – ANSI/UL |
|
![]() 20 lb CO2 Extinguisher 10B:C – ANSI/UL |
|
This blog was originally posted by Jason Hugo and Anna Hartenbach at QRFS.com/blog on June 8, 2017, and updated on February 1, 2019. If this article helped you learn a thing or two about fire extinguishers, check us out at Facebook.com/QuickResponseFireSupply or on Twitter @QuickResponseFS.