Need a replacement fire sprinkler system part? Our trained staff will help you find the right part, the first time. Call us at 888-361-6662.

Carlin Valve | 5" (127 mm) Storz Hydrant x 4" (101.6 mm) Storz Hose Connection

SKU
CV50FSX40SZ
Eliminate hydrant-to-pumper water hammer and make the most of your firefighting teams with the Model CV45A Carlin Valve, an automatic hydrant gate valve with a 5" (127 mm) Storz hydrant connection and a 4" (101.6 mm) Storz hose connection. Made in the USA!
$2,699.95
SKUInlet / Hydrant ConnectionOutlet / Hose ConnectionBody Material
CV50SZX40SZ 5" (127 mm) Storz Hydrant Connection 4" (101.6 mm) Storz Hose Connection A356.2-T6 Aluminum
Gate & Bonnet MaterialPrimerTop CoatFinish
535.2 Aluminum-Magnesium Alloy Mil-Spec High-Solids, VOC-Compliant Epoxy Polyamide High-Solids Aliphatic Two-Component Polyurethane Red Body with Black Bonnet
Availability
Usually Ships Within 48 Hours

Product Description

The Model CV45A Carlin Valve allows for full and swift opening of fire hydrants with virtually no risk of water hammer between the hydrant and the pumper. Designed for use with a 5" (127 mm) Storz hydrant nozzle, this pressure-activated hydrant gate valve fully opens only when the attached 4" (101.6 mm) Storz hose fully charges, giving the engine company the power to control hydrant flow from the fire scene—no batteries or radios required.

The Model CV45A Carlin Valve is made in the USA with globally sourced materials by Fyrelane USA, a Texas-based manufacturer with 40 years' experience developing products for water-based systems. This device flows water at 5 to 10% of the 5" (127 mm) Storz hydrant nozzle's capacity until the end of the 4" (101.6 mm) Storz hose opposite the hydrant closes—with a suction inlet valve, portable distribution manifold, or an approved hose clamp—and fully pressurizes.

To ensure proper flow rates, each Carlin Valve requires calibration and testing before use in accordance with instructions from Fyrelane USA. This valve features a 5" (127 mm) Storz hydrant connection and a 4" (101.6 mm) Storz hose connection with a high-strength, heat-treated A-356 aluminum body and a shock-resistant 535 aluminum-magnesium gate and bonnet.

This Carlin Valve is coated with an epoxy polyamide primer formulated for compliance with regulations limiting the use of volatile organic compounds (VOCs) and for corrosion-resistance in accordance with select military specifications. The primer is protected with a high-performance red polyurethane topcoat that resists corrosion and weathering in outdoor environments.

Technical Documents

Click here to view the data sheet for this Model CV45A Carlin Valve.

Click here to view the manual for this Model CV45A Carlin Valve.

Write Your Own Review
You're reviewing:Carlin Valve | 5" (127 mm) Storz Hydrant x 4" (101.6 mm) Storz Hose Connection
Your Rating