EPS10-1 Alarm Pressure Switch by System Sensor - UL & FM Approved!

SKU
ELPS101
System Sensor's EPS10-1 Pressure Switch sends an electrical signal when water discharges in plumbing and fire sprinkler systems. With adjustable sensitivity, a reinforced diagram, and a 1/2" (6.35 mm) NPT connection.
$112.50
  • Buy 2 for $106.88 each and save 5%
  • Buy 5 for $101.25 each and save 10%
  • Buy 10 for $95.63 each and save 15%
Part NumberPressure ConnectionMaximum Operating PressureMaximum Adjustment Pressure Range
ELPS101 1/2" (6.35 mm) Male NPT (MNPT) Glass-Reinforced Nylon 300 PSI 4 to 20 PSI
DimensionsService UseEnclosure RatingWarranty
5.12" H x 3.325" W x 4.250" L (13.0 cm x 8.4 cm x 10.8 cm) NFPA 13, NFPA 13D, NFPA 13R, NFPA 72 Rated UL 4x, NEMA 4 for indoor or outdoor use 3 Years
AvailabilityListings
Usually ships within 48 hours UL, ULC, FM, LPCB, CA Fire Marshall, VdS

Product Description

System Sensor's EPS10-1 Pressure Switch is designed to indicate discharge in water-based systems, including wet, dry, deluge, and pre-action automatic fire sprinkler systems. Featuring a weatherproof NEMA 4-rated enclosure and approvals from UL, ULC, FM, MEA, and California's Office of the State Fire Marshal, this durable Single-Switch Alarm Pressure Switch is suitable for indoor or outdoor use.

System Sensor's EPS10-1 Pressure Switch can be side-mounted or installed in the upright or horizontal position using the 1/2" (6.35 mm) NPT pressure connection. The reinforced diaphragm resists pressure spikes and features a sensitivity adjustment wheel for adjustable actuation pressures between 4 and 20 PSI.

Each alarm pressure switch includes tamper-resistant screws, a security wrench, and an SPDT switch. System Sensor's EPS10-1 Pressure Switch is factory set to trigger local alarms or a fire alarm control panel at pressures between 4 PSI and 8 PSI on rising or falling pressure.

Additional Specifications

Specifications 
Switch Contact Ratings 10.0 A, 1/2 HP @ 125/250 VAC. 2.5 A @ 6/12/24 VDC
Cover Tamper Switch UL Models: Optional P/N 546-8000. ULC Models: Factory Installed.
Shipping Weight 1.2 lbs (.54 kg)
Service Use NFPA 13, NFPA 13D, NFPA 13R, NFPA 72