Looking for the right fire sprinkler escutcheon for your sprinkler? Check out this FREE guide.

Exposed Double Clapper FDC "Standpipe" | 4" NPT x 2 1/2" NST x 2 1/2" NST Straight Brass

SKU
SDS2254BN
This Straight Exposed 4" (101.6 mm) NPT x 2 1/2" (63.5 mm) NST x 2 1/2" (63.5 mm) NST Cast Brass "Standpipe" Fire Department Connection (FDC) allows firefighters to supply water-based fire protection systems during an emergency. This UL-listed FDC features two National Standard Thread (NST) inlets capable of flows up to 250 gallons per minute for 500 total GPM.
$377.95
  • Buy 2 for $359.05 each and save 5%
  • Buy 5 for $340.16 each and save 10%
  • Buy 10 for $321.26 each and save 15%
FDC TypeFinishBrandingSwivel Hose Connection(s)
Straight Exposed Double-Clapper Cast Brass (Standard ASTM B30 C85700) "Standpipe" 2 1/2" (63.5 mm) NST
Outlet(s)DimensionsApprovals & ListingsOptional Accessories
4" (101.6 mm) NPT 11-21/32" W (29.6 cm) x 7-9/32" D (18.5 cm) UL, ULC, FM Brass accessories package contains one brass "Standpipe" identification plate and two brass plugs. Aluminum accessories package contains two aluminum breakcaps and one aluminum "Standpipe" identification plate.
SKUAvailability
SDS2254BN Usually Ships Within 48 Hours

Product Description

Straight Exposed 4" (101.6 mm) NPT x 2 1/2" (63.5 mm) NST x 2 1/2" (63.5 mm) NST Cast Brass "Standpipe" Fire Department Connection (FDC) saves lives and property when closed valves, natural disasters, pressure loss, or other problems interrupt the supply of water to fire sprinkler and standpipe systems. With a double-clapper design, cast brass finish, and solid brass components, this UL-listed FDC supports firefighting efforts by providing local fire officials with inlets used to pump water to fire sprinklers when primary water sources, such as a water supply tank, are exhausted.

Add-on parts for this exposed 4" (101.6 mm) NPT x 2 1/2" (63.5 mm) NST x 2 1/2" (63.5 mm) NST Cast Brass FDC are available in the drop-down menu above. The first option is a 4" diameter (101.6 mm) "Standpipe" brass identification plate and two 2 1/2" brass plugs and chain. The second option is a 4" "Standpipe" aluminum identification plate with two 2 1/2" aluminum breakable caps.

Exposed 4" (101.6 mm) NPT x 2 1/2" (63.5 mm) NST x 2 1/2" (63.5 mm) NST Cast Brass FDC inlet swivels utilize National Standard Thread (NST) and connect easily to fire hose connections throughout much of the United States. The National Pipe Thread (NPT) outlet installs to a wide range of plumbing and pipe fittings to streamline replacement of a broken, corroded, or unserviceable FDC. Two independent, self-closing brass clapper valves prevent backflow while allowing water to flow in from both inlets simultaneously.

This Exposed 4" (101.6 mm) NPT x 2 1/2" (63.5 mm) NST x 2 1/2" (63.5 mm) NST Cast Brass "Standpipe" FDC is ready for use with sprinkler systems in schools, high-rise buildings, apartment complexes, manufacturing facilities, and a wide range of other NFPA-compliant buildings. Each 2 1/2" (63.5 mm) inlet can supply up to 250 gallons per minute (GPM), allowing this FDC to deliver a total supply of up to 500 GPM.

Buildings requiring flows greater than 500 gallons per minute in accordance with NFPA 13 and NFPA 14 will need additional inlets, provided by additional single or double-inlet FDCs, or by installing a three-way, four-way, or six-way FDC.

Technical Documents

Click here to view the data sheet for this Straight Exposed 4" (101.6 mm) NPT x 2 1/2" (63.5 mm) NST x 2 1/2" (63.5 mm) NST Cast Brass "Standpipe" Fire Department Connection (FDC).

More Information
FDC Type Exposed
FDC Orientation Straight
Finish Brass
FDC Branding Standpipe
FDC Clapper Style Double
Number of FDC Inlets 2
FDC Inlet Size 2.5"
FDC Inlet Threads NST
FDC Outlet Size 4"
FDC Outlet Type Threaded
FDC Outlet Thread NPT
Write Your Own Review
You're reviewing:Exposed Double Clapper FDC "Standpipe" | 4" NPT x 2 1/2" NST x 2 1/2" NST Straight Brass
Your Rating