Exposed Double Clapper FDC "Auto Spkr" | 4" NPT x 3" NYFD x 3" NYFD Straight Brass

SKU
SDA2304BN
This Straight Exposed 4" (101.6 mm) NPT x 3" (76.2 mm) NYFD x 3" (76.2 mm) NYFD Cast Brass "Auto Spkr" Fire Department Connection (FDC) allows firefighters to supply water-based fire protection systems during an emergency. This UL & FM approved FDC features two New York Fire Department Thread (NYFD) inlets capable of flows up to 250 gallons per minute for 500 total GPM.
$257.95
  • Buy 2 for $245.05 each and save 5%
  • Buy 5 for $232.16 each and save 10%
  • Buy 10 for $219.26 each and save 15%
FDC TypeFinishBrandingSwivel Hose Connection(s)
Straight Exposed Double-Clapper Cast Brass "Auto Spkr" 3" (76.2 mm) NYFD
Outlet(s)DimensionsApprovals & ListingsOptional Accessories
4" (101.6 mm) NPT 7.56" (192.02 mm) Deep x 11.31" (287.27 mm) Wide UL, ULC, FM  Brass accessories package contains one brass "auto spkr" identification plate and two green plugs. Aluminum accessories package contains two green aluminum breakcaps and one red aluminum "auto spkr" identification plate.
SKUAvailability
SDA2304BN Usually Ships Within 48 Hours

Product Description

Straight Exposed 4" (101.6 mm) NPT x 3" (76.2 mm) NYFD x 3" (76.2 mm) NYFD Cast Brass "Auto Spkr" Fire Department Connection (FDC) saves lives and property when closed valves, natural disasters, pressure loss, or other problems interrupt the supply of water to fire sprinkler and standpipe systems. With a double-clapper design, cast brass finish, and solid brass components, this UL & FM approved FDC supports firefighting efforts by providing local fire officials with inlets used to pump water to fire sprinklers when primary water sources, such as a water supply tank, are exhausted.

Add-on parts for this exposed 4" (101.6 mm) NPT x 3" (76.2 mm) NYFD x 3" (76.2 mm) NYFD Cast Brass FDC are available in the drop-down menu above. The first option is a 4" diameter (101.6 mm) "Auto Spkr" brass identification plate and two 3" NYFD-threaded green-painted cast iron plugs and chain. The second option is a 4" "Auto Spkr" aluminum identification plate with two 3" green aluminum breakable caps. Exposed 4" (101.6 mm) NPT x 3" (76.2 mm) NYFD x 3" (76.2 mm) NYFD Cast Brass FDC inlet swivels utilize National Standard Thread (NST) and connect easily to fire hose connections throughout much of the United States.

Two included swivels feature New York Fire Department (NYFD) threads suitable for use in New York City. Two independent, self-closing brass clapper valves prevent backflow while allowing water to flow in from both inlets simultaneously. This FDC is 7.56" (192.02 mm) deep from outlet edge to swivel tip and 11.31" (287.27 mm) at its widest point with swivels installed.

This Exposed 4" (101.6 mm) NPT x 3" (76.2 mm) NYFD x 3" (76.2 mm) NYFD Cast Brass "Auto Spkr" FDC is ready for use with sprinkler systems in schools, high-rise buildings, apartment complexes, manufacturing facilities, and a wide range of other NFPA-compliant buildings. Each 3" (76.2 mm) inlet can supply up to 250 gallons per minute (GPM), allowing this FDC to deliver a total supply of up to 500 GPM.

Buildings requiring flows greater than 500 gallons per minute in accordance with NFPA 13 and NFPA 14 will need additional inlets, provided by additional single or double-inlet FDCs, or by installing a three-way, four-way, or six-way FDC.

Technical Documents

Click here to view the data sheet for this Straight Exposed 4" (101.6 mm) NPT x 3" (76.2 mm) NYFD x 3" (76.2 mm) NYFD Cast Brass "Auto Spkr" Fire Department Connection (FDC).

More Information
FDC Type Exposed
FDC Orientation Straight
Finish Brass
FDC Branding Auto Sprinkler
FDC Clapper Style Double
Number of FDC Inlets 2
FDC Inlet Size 3"
FDC Inlet Threads NYFD
FDC Outlet Size 4"
FDC Outlet Type Threaded
FDC Outlet Thread NPT