Fire Alarm Bell | 8 Inch| 24V DC | UL Listed!

SKU
AB08-24V
One of the loudest bells on the market, perfect for fire alarm systems, security systems, and schoolyards. With a 96-decibel sound audible from anywhere from 10 to 110 feet away, each offers a heavy-duty steel dome, a red enamel finish, and a UL listing for use with NFPA 72 fire alarm systems.
$40.25
  • Buy 5 for $37.03 each and save 8%
  • Buy 25 for $34.21 each and save 15%
  • Buy 50 for $30.19 each and save 25%

Alarm Bell | 8 Inch | 24V

Compact, loud, and outdoor-ready - perfect for fire sprinkler systems, flow and pressure switches, security systems, schoolyards, even alarm clocks!

Electrically compatible with most household and commercial wiring.

Easily defended against nesting birds, weather, and vandalism - especially when paired with a backbox and wire guard.

Listed for fire safety applications by UL.

Ordering

  • QRFS Part Number: AB08-24V

Dimensions

  • Gong diameter: 8 inch

Electrical Specifications

  • Voltage: 24 Volts AC
  • Rated Current: 100mA
  • Sound Level at 10 Feet: 98bD
  • Listing: UL (Audible Signal Appliances)

Appearance

  • Finish: Red Enamel

How loud is this alarm bell?

Alarm bells need to be louder than ambient sound levels to be heard. From ten feet away, this 98-decibel fire bell is louder than most lawnmowers. Here's how loud this bell sounds as the distance between it and the listener increases:

  • At 20 feet: 90 dB louder than many power tools
  • At 60 feet: 80 dB roughly the volume of a garbage disposal
  • At 110 feet: 75 dB more noise than a vacuum cleaner

These levels are loud enough to be heard at great distances in most businesses, restaurants, schools, and other buildings.

Which fire protection systems is this alarm bell designed for?

Most users connect this 24-volt DC fire bell to a fire alarm control panel. They serve as occupant notification devices, signals that facilitate evacuation. In compliance with the 2016 edition of NFPA 72: National Fire Alarm and Signaling Code, these fire alarm bells:

  • Are listed (18.3.1)
  • Have a nameplate with their electrical requirements and select installation rules (18.3.2)

This UL-listed device is recommended for use in apartments, dormitories, and with other residential systems. It's estimated to cover the following distances in compliance with NFPA 72:

  • Public mode (notifying everyone in an area): 10 feet with average ambient levels of 80 dB - or 35 feet at 70dB
  • Private mode (notifying staff tasked with evacuating a building's occupants): 10 feet with average ambient levels of 85dB - or 35 feet at average ambient levels of 75 dB
  • Sleeping area (waking sleeping residents): 10 feet with average ambient levels of 80 dB - or 35 feet at 70dB

This fire alarm bell can also be used as part of a sprinkler waterflow alarm when properly installed with flow or pressure switches.

Can this alarm bell be used in non-fire applications (security, timekeeping, and so on)?

Absolutely. But be safe: if you're at all unsure about doing this yourself, don't try. Seek assistance from a qualified electrician. These low-voltage, direct current (DC) bells are typically suitable when connecting to a control panel or a transformer (a device, often found with doorbells, that reduces voltage). For connecting directly to switches, buzzers, or a building's power supply, take a look at our 120-volt bells.

Can this alarm bell be installed outdoors?

With a heavy-duty steel dome housing and red enamel finish, this fire bell resists corrosion and is suitable for indoor or outdoor use. But leading fire safety codes require protection, both in the form of weatherproofing and guarding, for outdoor bells installed with fire sprinkler or fire alarm systems. You can add those to your cart above or browse our selection of fire bell accessories. For more, see the 2019 edition of NFPA 13, section 16.11.1.2 and the 2016 edition of NFPA 72, section 18.3.4.

How do I protect this bell against sources of failure (impact, nesting birds, worn wires, etc.)?

Available accessories for this fire alarm bell include:

  • Air-tight, weatherproof back boxes to protect wires and electronics.
  • Wire bell guards that wrap around the gong to shield against (light) impact and nesting birds.

More Information
Decibel Level 96dB