Reliable™ Model F1FR56 Quick Response Vertical Sidewall (RA1485) Fire Sprinkler Head
Sprinkler Identification Number (SIN): RA1485
This Vertical Sidewall sprinkler features a Brass finish and 155F (68C) activation temperature.
This Reliable™ Model F1FR56 Vertical Sidewall Fire Sprinkler is a quick response, standard coverage Vertical Sidewall fire sprinkler head, activating at 155F (68C) with a 5.6 K-Factor, and is rated for Light Hazard occupancies. Each Vertical Sidewall head features a heat-sensitive glass bulb assembly, standard 1/2 in. NPT threads, and a brass frame with a brass/bronze deflector.
This is a quick response, standard coverage, Vertical Sidewall sprinkler with a maximum working water pressure of 175 PSI (12 BAR) (cULus only). The RA1485 Model F1FR56 Sprinkler features a low profile and compact design. Using a heat-activated glass bulb assembly, this automatic fire sprinkler opens when ambient temperatures reach the sprinkler’s listed activation temperature, drenching the area surrounding a fire to keep it in its place of origin.
Reliable™ Model F1FR56 Fire Sprinkler RA1485 Sprinkler Head Listings and Approvals
Each F1FR56 sprinkler is made by Reliable™, a global leader in fire protection manufacturing for over 100 years. When installed properly, this RA1485 fire sprinkler head maintains listings and approvals:
cULus Listed
FM Approved
LPCB
UKCA: 0832-UKCA-CPR-S5045
Refer to the datasheet for listings and approvals in specific temperatures and/or applications.
When using Reliable™ Vertical Sidewall Sprinkler RA1485 for systems designed to NFPA 13, apply the listed areas of coverage and minimum water supply requirements shown in the manufacturer datasheet. This Vertical Sidewall sprinkler head has a maximum working pressure of 175 PSI (12 BAR) and connects to wet piping systems.
Reliable™ F1FR56 (RA1485) Vertical Sidewall Sprinkler Installation and Other Information
The RA1485 Vertical Sidewall Sprinkler is installed exposed in the Upright Vertical Sidewall or Pendent Vertical Sidewall orientation. Refer to the manufacturer data sheet for installation instructions with the approved Reliable™ accessories. During installation be aware that over tightening will cause permanent damage to the 1/2 in. NPT threads and/or the fire sprinklers themselves. Use the manufacturer approved installation wrench and tighten to a maximum torque of 14 ft-lb (19 N-m). Refer to the data sheet for additional installation and storage information.
Notes:
1. Listed and approved for Light Hazard ONLY.
2. LPCB approved for use in pendent position ONLY.
Available finish options include Brass, Chrome, and White.
White Polyester Finish (White) is UL Listed as corrosion resistant.
Temperature options include 135F (57C), 155F (68C), 175F (79C), 200F (93C), and 286F (141C). Finish and temperature combinations available in the “Options” section at the top of this product page.
The RA1485 listed wrenches include the approved Reliable™ Model W2, Model W14 (New frame with guard installed), and Model W13 (Legacy frame with guard installed). Add the correct wrench for your RA1485 installation. Sprinklers with Legacy frames require an alternative W13 wrench for proper installation.
Other listed accessories include Reliable™ sprinkler head guards and water shields, listed below and available at the top of this page. Prevent accidental activation or damage to your RA1485 sprinkler by installing the appropriate head guard and ensure the timely activation of your intermediate Vertical Sidewall sprinkler head by installing an appropriate water shield. Commonly purchased with fire sprinkler head cabinets and sprinkler shut off tools. These products are available in the “Frequently bought together” products section at the top of this product page.
Available Reliable™ RA1485 Vertical Sidewall Sprinklers & Listed Accessories:
Brass Finish
Reliable™ RA1485 Vertical Sidewall Sprinkler | QR | 5.6K | Brass | 175F | F1FR56V5BN
Reliable™ RA1485 Vertical Sidewall Sprinkler | QR | 5.6K | Brass | 200F | F1FR56V2BN
Reliable™ RA1485 Vertical Sidewall Sprinkler | QR | 5.6K | Brass | 286F | F1FR56V3BN
Reliable™ RA1485 Vertical Sidewall Sprinkler | QR | 5.6K | Brass | 135F | F1FR56V0BN
Reliable™ RA1485 Vertical Sidewall Sprinkler | QR | 5.6K | Brass | 155F | F1FR56V1BN
Chrome Finish
Reliable™ RA1485 Vertical Sidewall Sprinkler | QR | 5.6K | Chrome | 175F | F1FR56V5CN
Reliable™ RA1485 Vertical Sidewall Sprinkler | QR | 5.6K | Chrome | 200F | F1FR56V2CN
Reliable™ RA1485 Vertical Sidewall Sprinkler | QR | 5.6K | Chrome | 286F | F1FR56V3CN
Reliable™ RA1485 Vertical Sidewall Sprinkler | QR | 5.6K | Chrome | 135F | F1FR56V0CN
Reliable™ RA1485 Vertical Sidewall Sprinkler | QR | 5.6K | Chrome | 155F | F1FR56V1CN
White Finish
Reliable™ RA1485 Vertical Sidewall Sprinkler | QR | 5.6K | White | 155F | F1FR56V1WN
Reliable™ RA1485 Vertical Sidewall Sprinkler | QR | 5.6K | White | 175F | F1FR56V5WN
Reliable™ RA1485 Vertical Sidewall Sprinkler | QR | 5.6K | White | 200F | F1FR56V2WN
Reliable™ RA1485 Vertical Sidewall Sprinkler | QR | 5.6K | White | 286F | F1FR56V3WN
Reliable™ RA1485 Vertical Sidewall Sprinkler | QR | 5.6K | White | 135F | F1FR56V0WN
Wrenches:
W-2 Fire Sprinkler Wrench | WW2 | Vertical Sidewall
W-14 Fire Sprinkler Wrench | W14 | New frame with guard installed
W-13 Fire Sprinkler Wrench | W13 | Legacy frame with guard installed
Guards & Shields (New Frames):
F-2 Guard (FM)
Guards & Shields (Legacy Frames):
C1 Guard (FM)