SprinkFLEX Confined Space Elbow | 1/2 in. Sprinklers | 5 in.

SKU:
FDCSE5

No reviews yet Write a Review
$15.95
SprinkFLEX | 5" Confined Space Elbow | 125SFOLET
SprinkFLEX | 5" Confined Space Elbow | 125SFOLET
SprinkFLEX | 5" Confined Space Elbow | 125SFOLET - Threads
SprinkFLEX | 5" Confined Space Elbow | 125SFOLET - Side
SprinkFLEX | 5" Confined Space Elbow | 125SFOLET - Other Side
SprinkFLEX | 5" Confined Space Elbow | 125SFOLET - Close-Up Installed on Flexible Sprinkler Drop (Not Included)
SprinkFLEX | 5" Confined Space Elbow | 125SFOLET - Installed on Flexible Sprinkler Drop (Not Included)

  • Buy 10 - 99 and get 5% off
  • Buy 100 or above and get 15% off

Frequently Bought Together:

SprinkFLEX | 5" Confined Space Elbow | 125SFOLET
Inc. Tax
Ex. Tax

Overview

SprinkFLEX 90-Degree elbow is designed for installers placing non-concealed pendent fire sprinklers in confined spaces or areas with immovable obstructions. Simply install the stainless steel elbow to a SprinkFLEX flexible fire sprinkler drop assembly, and attach a head with 1/2 in. NPT threads. SprinkFLEX products are manufactured by Anvil International, a North American manufacturer of piping system products. QRFS offers a full selection of SprinkFLEX drop assemblies designed for use in NFPA 13-compliant fire sprinkler systems. This 5 in. confined space elbow for pendent sprinkler heads is made to:

  • Eliminate the need for additional clearance around fire sprinkler heads in buildings vulnerable to earthquakes

How should this 5 in. fire sprinkler elbow be used?

This stainless steel elbow is designed for use with SprinkFLEX flexible sprinkler drops. Pairing this 5 in. confined space elbow with a UL-listed, FM-approved SprinkFLEX assembly allows installers to precisely and safely position a 1/2 in. NPT fire sprinkler head. This 5 in. long elbow is recommended for use with non-concealed pendent sprinkler heads only. To install 1/2 in. NPT concealed pendent fire sprinklers, view our 3 in. confined space elbow. These elbows and drop assemblies may be installed accordance with NFPA 13, the product's listings, and the requirements of your local authority having jurisdiction (AHJ).

How do I install this 90-degree steel pipe elbow?

To install this 5 in. long, 90-degree fire sprinkler elbow:

  • Remove the sprinkler-threaded end of an existing SprinkFLEX drop
  • Connect the NPT-threaded end of the confined space elbow to the drop
  • Attach the NPT-threaded end of the drop to fire sprinkler piping
  • Screw the sprinkler head to the threaded end√Ǭ†in accordance with the√Ǭ†sprinkler√Ǭ†manufacturer's√Ǭ†instructions

SprinkFLEX is a registered trademark of SprinkFLEX, LLC and Anvil International.

Specifications

Reviews

No reviews yet

Customers Also Viewed

Pilot Clamp Replacement Head Pilot Clamp Replacement Head

Pilot Clamp Head

SKU : FP200REPH

$199.00
Replacement Head for Pilot Clamp Kits secures to vise grip clamps - included with pilot clamp kits - for drilling holes in pipes accurately. This head accommodates hole saw guides up to two inches in...
SprinklerVac: Touchless Fire Sprinkler Cleaning! SprinklerVac: Attachment that fits vacuums

SprinklerVac | Fire Sprinkler Cleaning Tool

SKU : SV001

$79.95
SprinklerVac: The Premier Fire Sprinkler Vacuum Attachment Transforms an ordinary vacuum into a safe and effective sprinkler cleaning tool Compatible with most household and commercial hoses...