Need a replacement fire sprinkler system part? Our trained staff will help you find the right part, the first time. Call us at 888-361-6662.

Victaulic Residential Fire Sprinkler 4.2K White Horizontal Sidewall 175F | V2738

SKU
V2738WH175
Victaulic V2738 Quick Response White Horizontal Sidewall Fire Sprinkler activates at 175F (79C) to defend intermediate hazard residential occupancies against fire. This UL & FM approved fire sprinkler features a 4.2K orifice and a 1/2" (15 mm) NPT connection.
$12.99
  • Buy 50 for $12.08 each and save 7%
  • Buy 100 for $11.43 each and save 12%
  • Buy 500 for $10.78 each and save 17%
Part NumberConstructionConnectionOrifice
V2738WH175 White Finish, Die-Cast Brass Frame, And Bronze Deflector 1/2" (15 mm) NPT 4.2K
Temperature RatingMaximum Working PressureApprovals and ListingsAvailability
175F (79C) 175 PSI (12.1 BAR) UL, ULC, FM, LPCB, NYC In Stock

 

Product Description

Victaulic V2738 Quick Response White Horizontal Sidewall Fire Sprinkler delivers dependable, competitively-priced protection against fire in intermediate hazard residential occupancies such as homes, apartments, dormitories, and hotels. Using a heat-activated 3mm glass bulb, this automatic fire sprinkler opens when ambient temperatures reach 175F (79C), lowering ambient temperatures to reduce flashover and facilitating safe escape or rescue.

The Victaulic Model V2738 has a 4.2 K-Factor and installs with 1/2" (15 mm) National Pipe Thread (NPT), used in fire sprinkler systems throughout the United States. This Quick Response Fire Sprinkler features a white finish, die-cast brass frame, bronze deflector, and a beryllium nickel spring with PTFE-taped seal.

With a maximum working pressure of 175 PSI (12.1 BAR), this horizontal sidewall sprinkler installs on a wall or the side of a beam where ceiling piping is not desirable and may be installed and used in accordance with NFPA 13, NFPA 13R, NFPA 13D and local fire code. Each Model V2738 sprinkler is made by Victaulic, a piping-industry manufacturer and trusted producer of fire protection products since 1919.

This product is UL & FM approved for use in fire protection systems when accepted by the authority having jurisdiction.

 

Technical Documents

Click here to view the data sheet for the Victaulic V2738 Quick Response White Horizontal Sidewall Fire Sprinkler.

Write Your Own Review
You're reviewing:Victaulic Residential Fire Sprinkler 4.2K White Horizontal Sidewall 175F | V2738
Your Rating