Looking for the right fire sprinkler escutcheon for your sprinkler? Check out this FREE guide.

Victaulic Fire Sprinkler 5.6K Chrome Horizontal Sidewall QR 155F | V2710

SKU
V2710CH155
Victaulic V2710 Quick Response Chrome Horizontal Sidewall Fire Sprinkler activates at 155F (68C) to defend ordinary hazard commercial occupancies against fire. This UL & FM approved fire sprinkler features a 5.6K orifice and a 1/2" (15 mm) NPT connection.
$20.95
  • Buy 50 for $19.48 each and save 7%
  • Buy 100 for $18.44 each and save 12%
  • Buy 500 for $17.39 each and save 17%
Part NumberConstructionConnectionOrifice
V2710CH155Chrome Finish, Die-Cast Brass Frame, And Commercial Bronze Deflector1/2" (15 mm) NPT5.6K
Temperature RatingMaximum Working PressureApprovals and ListingsAvailability
155F (68C)175 PSI (12.1 BAR)UL, ULC, FM, LPCB, NYCIn Stock

Product Description

Victaulic V2710 Quick Response Chrome Horizontal Sidewall Fire Sprinkler delivers dependable, competitively-priced protection against fire in ordinary hazard commercial occupancies such as universities, auditoriums, churches, and parking garages. Using a heat-activated 3mm glass bulb, this automatic fire sprinkler opens when ambient temperatures reach 155F (68C), lowering ambient temperatures to reduce flashover and facilitating safe escape or rescue.

The Victaulic Model V2710 has a 5.6 K-Factor and installs with 1/2" (15 mm) National Pipe Thread (NPT), used in fire sprinkler systems throughout the United States. This Quick Response Fire Sprinkler features a chrome finish, die-cast brass frame, low-silicon bronze screw, commercial bronze deflector, and a beryllium nickel spring with PTFE-taped seal.

This 155F (68C) temperature rating strikes a balance between a fire sprinkler that activates too soon, causing accidental discharge, and too late. 155F (68C) Quick Response Fire Sprinklers are preferred for use in theaters, restaurants, and other gathering spaces where human safety is the first priority. The Victaulic Model V2710 is also perfect for use in animal shelters, agricultural and food processing facilities, and fairgrounds.

With a maximum working pressure of 175 PSI (12.1 BAR), this horizontal sidewall sprinkler installs on a wall or the side of a beam where ceiling piping is not desirable and may be installed and used in accordance with NFPA 13 and local fire code. Each Model V2710 sprinkler is made by Victaulic, a piping-industry manufacturer and trusted producer of fire protection products since 1919.

This product is UL & FM approved for use in fire protection systems when accepted by the authority having jurisdiction. In accordance with NFPA 13, a higher temperature rating may be required when installing aquick response fire sprinkler in or near heat sources, unventilated spaces, uncovered steam mains, or uninsulated rooftops.

Technical Documents

Click here to view the data sheet for the Victaulic V2710 Quick Response Chrome Horizontal Sidewall Fire Sprinkler.

Write Your Own Review
You're reviewing:Victaulic Fire Sprinkler 5.6K Chrome Horizontal Sidewall QR 155F | V2710
Your Rating