Victaulic V27 Horizontal Sidewall Fire Sprinkler | V2710 | Quick Response | 5.6K | White | 155F

SKU:
V2710WH155

No reviews yet Write a Review
$18.99
Victaulic Fire Sprinkler 5.6K White Horizontal Sidewall QR 155F | V2710
Victaulic Fire Sprinkler 5.6K White Horizontal Sidewall QR 155F | V2710
Victaulic Fire Sprinkler 5.6K White Horizontal Sidewall QR 155F | V2710 - Side
Victaulic Fire Sprinkler 5.6K White Horizontal Sidewall QR 155F | V2710 - Other Side
Victaulic Fire Sprinkler 5.6K White Horizontal Sidewall QR 155F | V2710 - Threads
Deflector of Victaulic Fire Sprinkler 5.6K White Horizontal Sidewall QR 155F | V2710

  • Buy 100 - 399 and get 5% off
  • Buy 400 or above and get 8% off

Frequently Bought Together:

Victaulic Fire Sprinkler 5.6K White Horizontal Sidewall QR 155F | V2710
Inc. Tax
Ex. Tax

Overview

Victaulic V2710 Quick Response White Horizontal Sidewall Fire Sprinkler delivers dependable, competitively-priced protection against fire in ordinary-temperature applications. Using a heat-activated 3mm glass bulb, this automatic fire sprinkler opens when ambient temperatures reach 155F (68C), lowering ambient temperatures to reduce flashover and facilitating safe escape or rescue.

The Victaulic Model V2710 has a 5.6 K-Factor and installs with 1/2 in. (15 mm) National Pipe Thread (NPT), used in fire sprinkler systems throughout the United States. This Quick Response Fire Sprinkler features a white finish, die-cast brass frame, low-silicon bronze screw, commercial bronze deflector, and a beryllium nickel spring with PTFE-taped seal.

With a maximum working pressure of 175 PSI (12.1 BAR), this horizontal sidewall sprinkler installs on a wall or the side of a beam where ceiling piping is not desirable and may be installed and used in accordance with NFPA 13 and local fire code. Each Model V2710 sprinkler is made by Victaulic, a piping-industry manufacturer and trusted producer of fire protection products since 1919.

This product is UL listed & FM approved for use in fire protection systems when accepted by the authority having jurisdiction. In accordance with NFPA 13, a higher temperature rating may be required when installing a quick response fire sprinkler in or near heat sources, unventilated spaces, uncovered steam mains, or uninsulated rooftops.

Specifications

Finish:
White
Response Type:
Quick Response
Temperature:
155F
Corrosion Resistance:
No
May Contain Lead:
No
Nominal K-Factor:
5.6K
Fire Sprinkler Heat Element:
Glass Bulb
Fire Sprinkler Use Type:
Commercial
Fire Sprinkler Head Type:
Horizontal Sidewall
SIN Number:
V2710
Thread Type:
NPT
Model:
V27
UL Listed/FM Approved:
Yes

Data & Resources