Victaulic V38 Cover Plate | Cleanroom | White | 135F

SKU:
FCPWH135CL

No reviews yet Write a Review
$27.25
Victaulic V38 Cover Plate | Cleanroom | White | 135F
Victaulic V38 Cover Plate | Cleanroom | White | 135F
Victaulic V38 Cover Plate | Cleanroom | White | 135F
Victaulic V38 Cover Plate | Cleanroom | White | 135F
Victaulic V38 Cover Plate | Cleanroom | White | 135F
Victaulic V38 Cover Plate | Cleanroom | White | 135F
Victaulic V38 Cover Plate | Cleanroom | White | 135F
Victaulic V38 Cover Plate | Cleanroom | White | 135F

  • Buy 10 - 99 and get 5% off
  • Buy 100 or above and get 15% off

Frequently Bought Together:

Victaulic V38 Cover Plate | Cleanroom | White | 135F
Inc. Tax
Ex. Tax

Overview

White 135F (57C) Cover Plate Assembly with Cleanroom Air and Dust Seal for Victaulic Model V38 Fire Sprinklers activates at 135F (57C) to facilitate timely activation of fire sprinkler heads with temperatures rated at 135F (57C) to 155F (68C). A special gasket prevents debris from entering a protected area and is designed for use in cleanrooms.

Sprinkler Identification Numbers (SIN) for this White 135F (57C) Cover Plate Assembly for Victaulic Model V38 Fire Sprinklers include:

    V3801
  • V3804
  • V3807
  • V3808

This Off-White 135F (57C) Cover Plate Assembly for Victaulic Model V38 Fire Sprinklers is listed by UL, FM, and/or other organizations, depending on the sprinkler. When this white fire sprinkler cover plate reaches a specified temperature the solder holding the plate's decorative exterior on the frame melts, and the two separate. Cover plates in stock finishes other than white are available on our site, and custom-finished may be available by special order - call us at 888-361-6662 or click here to contact us.

For many cover plates, the rated temperature is at least 20F (6.7C) cooler than the sprinkler head's activation temperature, which ensures that the cover plate detaches early enough to allow the sprinkler to activate on time. However, each manufacturer's product line varies slightly and cover plate temperatures may be closer to or further away from the fire sprinkler's activation temperature. Use only the cover plate approved by the manufacturer for your specific sprinkler.

Fire Sprinkler Helpful Tips:

Tip 1: When replacing cover plates it is important to purchase replacements from the same manufacturer as the fire sprinkler. Each manufacturer's plate is a little different in size, color, and so on. The manufacturer and temperature of a cover plate is printed on the base of the plate. To view this information, remove the cover plate. Most cover plates are either twist off or pull off.

Tip 2: Any modifications or replacements to a fire sprinkler system should be performed by qualified professionals.

Tip 3: National Fire Protection Association (NFPA) guidelines state that spare fire sprinkler heads and a wrench should be accessible at all times in a facility with a commercial fire sprinkler system installed. Often, state regulations also apply. Check with your local fire department.

Tip 4: All fire sprinkler systems should be visually inspected (often) and professionally inspected (annually).

Specifications

Finish:
White
Temperature:
135F
SIN Number:
sin_number=V3801, sin_number=V3802, sin_number=V3804, sin_number=3806, sin_number=V3807, sin_number=V3808
Model:
V38
UL Listed/FM Approved:
Yes
Inner Diameter:
2-1/16 in.
Outer Diameter:
3-1/4 in.