Viking FREEDOM Residential 4.9K Domed Concealed Pendent 155F | VK468D

SKU
VK468DCP155
Viking VK468-D Residential Fast Response Concealed Pendent Fire Sprinkler activates at 155F (68C) to defend ordinary hazard residential occupancies against fire. This UL-listed fire sprinkler features a 4.9K orifice and a 1/2" (12.7 mm) NPT connection.
$27.99
  • Buy 50 for $26.03 each and save 7%
  • Buy 100 for $24.63 each and save 12%
  • Buy 500 for $23.23 each and save 17%
Part Number Construction Connection Orifice
VK468DCP155 Brass Body And Brass Or Phosphor Bronze Deflector 1/2" (12.7 mm) NPT 4.9K
Temperature Rating Approvals Cover Plate Activation Temperature Cover Plate Finish
155F (68C) cULus, NYC, NSF 135F (57C) Choice of White, Ivory, Black, Antique Brass, Brushed Brass, Brushed Chrome, Bright Brass, Polished Chrome, or Brushed Copper. Custom Finishes by Special Order.
Maximum Working Pressure Availability
175 PSI (12.1 BAR) Usually ships within 48 hours

 Product DescriptionViking VK468-D Residential Fast Response Concealed Pendent Fire Sprinkler delivers decorative, competitively-priced defense against fire in ordinary hazard residential occupancies such as homes, apartments, dormitories, and hotels. Using a heat-activated 3mm glass bulb, this automatic fire sprinkler opens when ambient temperatures reach 155F (68C), reducing the likelihood of flashover and facilitating safe evacuation. Designed for residential applications, the 4.9K orifice makes efficient use of available water supplies in smaller sprinkler systems.The included low-profile cover plate mounts flush to nearby walls and is available in a custom finish by special order or in one nine standard finishes, including: white, ivory, black, antique brass, brushed brass, brushed chrome, bright brass, polished chrome, or brushed copper. When temperatures near the ceiling reach 135F (57C), the soldered cover plate detaches, exposing the head of the Viking VK468-D concealed pendent fire sprinkler, which activates when temperatures reach 155F (68C).The Viking Model VK468-D has a 4.9 K-Factor and installs with 1/2" (12.7 mm) National Pipe Thread (NPT), used in fire sprinkler systems throughout the United States. This Residential Fast Response Fire Sprinkler features a brass body, brass or phosphor bronze deflector, and abrass cover plate. This sprinkler features a "push-on, thread-off" cover plate design, provides up to 1/2" (12.7 mm) of vertical adjustment, and the cover assembly easily removes to permit temporary re.To order the Viking VK468-D with custom cover plates, contact us at 888.361.6662 or fill our our contact form.This 155F (68C) temperature rating strikes a balance between a fire sprinkler that activates too soon, causing accidental discharge, and too late. 155F (68C) Residential Fast Response Fire Sprinklers can be installed to wet and dry pipe fire sprinkler systems, and are preferred for use in one and two-family dwellings, apartments, duplexes, and boarding houses when a low profile is desirable. The Viking Model VK468-D is also a suitable choice for installation in many college dormitories, condominiums, and nursing homes.With a maximum working pressure of 175 PSI (12.1 BAR), this pendent sprinkler hangs from above-ceiling piping behind a decorative cover plate and may be installed and used in accordance with NFPA 13, NFPA 13R, NFPA 13D and local fire code. Each Model VK468-D sprinkler is made by Viking, a global leader in fire protection manufacturing for nearly 100 years.This product is UL-listed, and appropriate for use in fire protection systems when accepted by the authority having jurisdiction. In accordance with NFPA 13, a higher temperature rating may be required when installing a residential fast response fire sprinkler in or near heat sources, unventilated spaces, uncovered steam mains, or uninsulated rooftops. Concealed pendent sprinklers s Technical DocumentsClick here to view the data sheet for the Viking VK468-D Residential Fast Response Concealed Pendent Fire Sprinkler.