Viking™ VK108 Upright Sprinkler | SR | 5.6K | White | 286F | 1/2 in. NPT | 12973MG/W

SKU:
VK108WH286
Manufacturer Part Number:
12973MG/W
$15.99
  • Fire Sprinkler Wrench | Viking™ Frame-Style | Standard | 21475M/B | QRFS™ | Hero

FAST SHIPPING: In stock items ship SAME DAY if ordered before 3PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS™ SKU:
VK108WH286
Manufacturer Part Number:
12973MG/W
Manufacturer:
Viking™
SIN:
VK108
Model:
Micromatic
Head Type:
Upright
Finish:
White
Finish Detail:
White-Polyester
Size:
1/2 in.
Size Detail:
1/2 in. NPT Sprinkler
K Factor:
5.6K
Response Type:
Standard Response (SR)
Temperature:
286F
Heat Element:
Fusible Link
Coverage:
Standard Coverage
Material:
Brass Frame, Brass Deflector
Corrosion Resistant:
Yes
May Contain Lead:
Yes
UL Listed:
Yes
FM Approved:
Yes
Occupancy Type:
Light, Ordinary, Extra Hazard
Maximum Working Water Pressure:
175 PSI
Sourced Location:
USA

Viking™ VK108 Micromatic Standard Response Fusible Link Upright Sprinkler | SR | 5.6K | White | 286F | 1/2 in. NPT | 12973MG/W | QRFS™ | Hero

Overview

Viking™ Micromatic Model M Standard Response Upright (VK108) Fire Sprinkler Head

Sprinkler Identification Number (SIN): VK108

This Upright sprinkler features a White finish and 286F (141C) temperature.

This Viking™ Micromatic Model M Upright Fire Sprinkler is a standard coverage Upright fire sprinkler head, activating at 286F (141C) with a 5.6 K-Factor, and is rated for Light, Ordinary, and Extra Hazard occupancies. Each Upright head features a heat-sensitive fusible link assembly, standard 1/2 in. NPT threads, and a brass frame with a brass deflector.

This is a standard response, standard coverage, Upright sprinkler with a maximum working water pressure of 175 PSI (12 BAR). The VK108 Micromatic Model M Sprinkler features a low profile and compact design. Using a heat-activated fusible link assembly, this automatic fire sprinkler opens when ambient temperatures reach the sprinkler’s listed activation temperature, drenching the area surrounding a fire to keep it in its place of origin.

Viking™ Micromatic Model M Fire Sprinkler VK108 Sprinkler Head Listings and Approvals

Each Micromatic Model M sprinkler is made by Viking™, a global leader in fire protection manufacturing. When installed properly, this VK108 fire sprinkler head maintains listings and approvals:

cULus, FM

Refer to the datasheet for listings and approvals in specific temperatures and/or applications.

When using Viking™ Upright Sprinkler VK108 for systems designed to NFPA standards, apply the listed areas of coverage and minimum water supply requirements shown in the manufacturer datasheet. This Upright sprinkler head has a maximum working pressure of 175 PSI (12 BAR) and connects to wet piping systems.

Viking™ (VK108) Micromatic Model M Upright Sprinkler Installation and Other Information

The VK108 Upright Sprinkler is installed exposed in the Upright orientation. Refer to the manufacturer data sheet for installation instructions with the approved Viking™ accessories. During installation be aware that over tightening will cause permanent damage to the 1/2 in. NPT threads and/or the fire sprinklers themselves. Use the manufacturer approved installation wrench and tighten to a maximum torque of 14 ft-lb (19 N-m). Refer to the data sheet for additional installation and storage information.

Available finish options include Brass, Chrome, White, and Black.
Temperature options include 165F (74C), 220F (104C), and 286F (141C).

The VK108 listed wrenches include the approved Viking™ Standard Sprinkler Wrench (21475M/B). Add the correct wrench for your VK108 Upright installation.

Other listed accessories include Viking™ sprinkler escutcheon and water shields, listed below and available at the top of this page. Commonly purchased with fire sprinkler head cabinets and sprinkler shut off tools.

Available Viking™ VK108 Upright Sprinklers & Listed Accessories:

Viking™® VK108 Upright Sprinkler | SR | 5.6K | Brass | 165F | 1/2 in. NPT | 12973AC
Viking™® VK108 Upright Sprinkler | SR | 5.6K | Brass | 220F | 1/2 in. NPT | 12973AF
Viking™® VK108 Upright Sprinkler | SR | 5.6K | Brass | 286F | 1/2 in. NPT | 12973AG

Viking™® VK108 Upright Sprinkler | SR | 5.6K | Chrome | 165F | 1/2 in. NPT | 12973FC
Viking™® VK108 Upright Sprinkler | SR | 5.6K | Chrome | 220F | 1/2 in. NPT | 12973FF
Viking™® VK108 Upright Sprinkler | SR | 5.6K | Chrome | 286F | 1/2 in. NPT | 12973FG

Viking™® VK108 Upright Sprinkler | SR | 5.6K | White | 165F | 1/2 in. NPT | 12973MC/W
Viking™® VK108 Upright Sprinkler | SR | 5.6K | White | 220F | 1/2 in. NPT | 12973MF/W
Viking™® VK108 Upright Sprinkler | SR | 5.6K | White | 286F | 1/2 in. NPT | 12973MG/W

Viking™® VK108 Upright Sprinkler | SR | 5.6K | Black | 165F | 1/2 in. NPT | 12973MC/B
Viking™® VK108 Upright Sprinkler | SR | 5.6K | Black | 220F | 1/2 in. NPT | 12973MF/B
Viking™® VK108 Upright Sprinkler | SR | 5.6K | Black | 286F | 1/2 in. NPT | 12973MG/B


Wrenches:
Viking™ Standard Sprinkler Wrench| 21475M/B | Upright

Reviews
No reviews yet
Product Alternatives