Flush Double Clapper FDC "Standpipe" | 4" NPT x 2 1/2" NST x 2 1/2" NST Chrome
- Buy 2 for $420.80 each and save 5%
- Buy 5 for $398.66 each and save 10%
- Buy 10 for $376.51 each and save 15%
FDC Type | Orientation | Finish | Identification Plate |
---|---|---|---|
Flush Double-Clapper | Optional Back/Bottom/Top Outlet | Polished Chrome | "Standpipe" |
Inlet(s) | Outlet(s) | Approvals & Listings | Back Outlet Orientation Dimensions |
---|---|---|---|
Two open adapters with 2 1/2" (63.5 mm) rigid NPT x 2 1/2" (63.5 mm) NST swivels | 4" (101.6 mm) NPT | UL, ULC | 11" (279.4 mm) W x approximately 5 3/8" (13.65 cm) H x 7 1/8" (180.975 mm) D |
Top/Bottom Orientation Dimensions | Kit Contents | SKU | Availability |
---|---|---|---|
10 1/2" (266.7 mm) W x 7 3/8" (187.325 mm) H x 5 1/8" (130.175 mm) D | Body with NPT outlet and NPT inlets, two open adapters with 2 1/2" (63.5 mm) rigid NPT x 2 1/2" (63.5 mm) NST hose thread, two NST-threaded brass plug and chain assemblies, and a polished chrome "standpipe" identification plate | FCS25 | Usually Ships Within 48 Hours |
Product Description
Flush 4" (101.6 mm) NPT x 2 1/2" (63.5 mm) NST x 2 1/2" (63.5 mm) NST Polished Chrome "Standpipe" Fire Department Connection (FDC) saves lives and property when closed valves, natural disasters, pressure loss, or other problems interrupt the supply of water to standpipe systems. With a double-clapper design, polished chrome finish, and solid brass components, this UL & ULC-listed FDC supports firefighting efforts by providing local fire officials with inlets used to pump water to fire sprinklers or in-building hose connections when primary water sources, such as a water supply tank, are exhausted.
Each Flush 4" (101.6 mm) NPT x 2 1/2" (63.5 mm) NST x 2 1/2" (63.5 mm) NST Polished Chrome FDC is sold as a kit containing an NPT x NPT body (NPT inlets with an NPT outlet), two open adapters with 2 1/2" (63.5 mm) rigid NPT x 2 1/2" (63.5 mm) NST hose thread, two NST-threaded brass plug and chain assemblies, and a polished chrome "Standpipe" identification plate. Inlet swivels utilize National Standard Thread (NST) and connect easily to fire hose connections throughout much of the United States.
This Flush 4" (101.6 mm) NPT x 2 1/2" (63.5 mm) NST x 2 1/2" (63.5 mm) NST Polished Chrome "Standpipe" FDC is available in a straight (back outlet) orientation or in a 90-degree angled orientation (bottom/top outlet) for easy connection to existing piping. The bulk of a flush fire department connection typically installs behind an exterior wall, providing a lower-profile design than that of an exposed or freestanding connection. The National Pipe Thread (NPT) outlet installs to a wide range of plumbing and pipe fittings across the United States to streamline replacement of a broken, corroded, or unserviceable FDC.
When ordered with a Back Outlet (angled) orientation, this FDC's body is 11" (27.94 cm) wide, approximately 5 3/8" (13.65 cm) tall, 7 1/8" (18.1 cm) deep from inlet to outlet, and has a distance of 7" (17.78 cm) from inlet center to inlet center. When ordered with a Top/Bottom orientation, this FDC's body is 10 1/2" (26.67 cm) wide, 7 3/8" (18.73 cm) tall, 5 1/8" (13.02 cm) deep from inlet to outlet, and has a distance of 7" (mm) between inlet centers. These dimensions apply to the body only and are not an accurate indication product's full size after the installation of open adapters, plug and chain assemblies, and the identification plate.
This Flush 4" (101.6 mm) NPT x 2 1/2" (63.5 mm) NST x 2 1/2" (63.5 mm) NST Polished Chrome "Standpipe" FDC is ready for use with sprinkler systems in schools, high-rise buildings, apartment complexes, manufacturing facilities, and a wide range of other NFPA-compliant buildings. "Standpipe" signage suitably marks this FDC for use with standpipe systems designed and installed in accordance with NFPA 13 and NFPA 14. The accompanying identification plate is 15" (38.1 cm) wide, 9" (22.86 cm) tall, and 4 1/2" (11.43 cm) from inlet hole center to plate top, with letters 1" (25mm) or larger cast on the polished-brass plate.
Each 2 1/2" (63.5 mm) inlet can supply up to 250 gallons per minute (GPM), allowing this Flush 4" (101.6 mm) NPT x 2 1/2" (63.5 mm) NST x 2 1/2" (63.5 mm) NST Polished Chrome "Standpipe" FDC to deliver a total supply of up to 500 GPM.Two independent, self-closing brass clapper valves prevent backflow while allowing water to flow in from both inlets simultaneously.
This Flush 4" (101.6 mm) NPT x 2 1/2" (63.5 mm) NST x 2 1/2" (63.5 mm) NST Polished Chrome "Standpipe" Fire Department Connection is also suitable for use with Class I automatic wet standpipes and Class III standpipe systems, found in underground buildings, concert halls, malls, marinas, and other structures. Buildings requiring flows greater than 500 gallons per minute in accordance with NFPA 13 and NFPA 14 will need additional inlets, provided by additional single or double-inlet FDCs, or by installing a three-way, four-way, or six-way FDC.
Technical Documents
FDC Type | Flush |
---|---|
FDC Orientation | Optional Back/Bottom/Top Outlet |
Finish | Chrome |
Identification Plate Lettering | "Standpipe" |
FDC Clapper Style | Double |
Number of FDC Inlets | 2 |
FDC Inlet Size | 2.5" |
FDC Inlet Threads | NST |
FDC Outlet Size | 4" |
FDC Outlet Type | Threaded |
FDC Outlet Thread | NPT |