CPVC Tee | Slip x Slip x Slip | 1-1/2 in.

SKU:
TCPVCST5

No reviews yet Write a Review
$5.59
1 1/2" (38.1 mm) CPVC Slip x Slip x Slip Tee
1 1/2" (38.1 mm) CPVC Slip x Slip x Slip Tee
Angled View of 1 1/2" (38.1 mm) CPVC Slip x Slip x Slip Tee
Inlet of 1 1/2" (38.1 mm) CPVC Slip x Slip x Slip Tee
Side View of 1 1/2" (38.1 mm) CPVC Slip x Slip x Slip Tee
Bottom Inlet of 1 1/2" (38.1 mm) CPVC Slip x Slip x Slip Tee

  • Buy 10 - 49 and get 5% off
  • Buy 50 or above and get 15% off

Frequently Bought Together:

1 1/2" (38.1 mm) CPVC Slip x Slip x Slip Tee
Inc. Tax
Ex. Tax

Overview

1-1/2 in. (38.1 mm) CPVC Slip x Slip x Slip Tee is a corrosion-resistant CPVC thermoplastic fitting for use with fire sprinkler pipe. This CPVC tee features three 1-1/2 in. (38.1 mm) female socket connections used to split the flow of water into two directions.

Each 1-1/2 in. (38.1 mm) CPVC Slip x Slip x Slip Tee is made in the USA by Thermafit Industries, Inc., a California-based manufacturer of plumbing and fire sprinkler pipe fittings. This tee has a working pressure rating of 175 PSI at 150F (65C) and is suitable for installation in NFPA 13, NFPA 13D, and NFPA 13R systems where allowed by state and local law.

1-1/2 in. (38.1 mm) CPVC Slip x Slip x Slip Tee is intended for use in light hazard NFPA 13 occupancies, residential NFPA 13R occupancies, and home fire sprinkler systems in accordance with NFPA 13D. This product is UL-listed for use in wet-pipe automatic fire sprinkler systems in combination with UL-listed CPVC products.

1-1/2 in. (38.1 mm) CPVC Slip x Slip x Slip Tee is backed by Thermafit's ten-year warranty from the date of shipment.

Dimensions

CPVC Tee Dimensions

  • A: 1.912 in.
  • B: 1.894 in.
  • C: 1.094 in. (Schedule 40) or 1.375 in. (Schedule 80)
  • G: 1.190 in.
  • H: 2.568 in.
  • L: 5.125 in.
  • M: 2.344 in.

Specifications

Material:
CPVC
Pipe Fitting Type:
Tee
UL Listed/FM Approved:
No

Data & Resources

Reviews

No reviews yet

Customers Also Viewed

1" (25.4 mm) CPVC Slip x Slip x Slip Tee | Sprinkler Pipe Fitting 1" (25.4 mm) CPVC Slip x Slip x Slip Tee | Sprinkler Pipe Fitting

CPVC Tee | Slip x Slip x Slip | 1 in.

SKU : TCPVCST3

$2.25
1 in. (25.4 mm) CPVC Slip x Slip x Slip Tee is a corrosion-resistant CPVC thermoplastic fitting for use with fire sprinkler pipe. This CPVC tee features three 1 in. (25.4 mm) female socket...
1 1/2" (38.1 mm) CPVC Slip x Slip Coupling 1 1/2" (38.1 mm) CPVC Slip x Slip Coupling

CPVC Coupling | Slip x Slip | 1-1/2 in.

SKU : TCPVCSC5

$2.75
1-1/2 in. CPVC Slip x Slip Coupling is a corrosion and heat-resistant CPVC fitting designed for use with fire sprinkler piping. This CPVC coupling features two 1-1/2 in. (38.1 mm) female socket...
1" (25.4 mm) CPVC 90-Degree Slip x Slip Elbow 1" (25.4 mm) CPVC 90-Degree Slip x Slip Elbow

CPVC Elbow, 90 Degree | Slip x Slip | 1 in.

SKU : TCPVC9E3

$1.81
1 in. CPVC 90-Degree Slip x Slip Elbow is a corrosion-resistant CPVC thermoplastic fitting for use with fire sprinkler pipe. This 90-degree CPVC elbow features two 1 in. (25.4 mm) female socket...
CPVC Glue | One-Step Cement | 1 Pint CPVC Glue | One-Step Cement | 1 Pint

CPVC Glue | One-Step Cement | 1 Pint

SKU : TFI1PCPGLUE

$17.99
CPVC Glue forms a water-tight seal between CPVC pipes, fittings, couplings, elbows, and other components used in the construction of fire sprinkler systems. This pint of one-step solvent cement...