Senju Residential Fire Sprinkler 3.7K Concealed Pendent 205F | SS8261

SKU
SS8261CP205
Senju RC-RES Residential Fast Response Concealed Pendent Fire Sprinkler activates at 205F (96C) to defend intermediate hazard residential occupancies against fire. This UL-listed fire sprinkler features a 3.7K orifice and a 1/2" (12.7 mm) NPT connection.
$39.95
  • Buy 50 for $37.15 each and save 7%
  • Buy 100 for $35.16 each and save 12%
  • Buy 500 for $33.16 each and save 17%
Part Number Construction Connection Orifice
SS8261CP205 Copper Alloy Body And Phosphor Bronze Deflector 1/2" (12.7 mm) NPT 3.7K
Temperature Rating Sprinkler Wrench Maximum Working Pressure Approvals and Listings
205F (96C) Wrench - Senju Socket Head for HF Heads 175 PSI (12.1 BAR) cULus, NSF/ANSI/CAN 61, NSF/ANSI 372
Availability
Standard orders usually ship within 48 hours

 

Product Description

Senju RC-RES Residential Fast Response Concealed Pendent Fire Sprinkler delivers decorative, affordable defense against fire in intermediate hazard residential occupancies such as homes, apartments, dormitories, and hotels. Using a heat-activated compressed fusible solder, this automatic fire sprinkler opens when ambient temperatures reach 205F (96C), reducing the likelihood of flashover and facilitating safe evacuation.

Low-profile cover plates mount flush to the ceiling and are available with a painted wood finish, metallic finish, or simple colors. Custom-colored cover plates are available by special order when ordering in quantities larger than 100 units (a $325 paint set-up fee applies). When temperatures near the ceiling reach 162F (72C), the soldered cover plate detaches, exposing the head of the Senju RC-RES concealed pendent fire sprinkler, which activates when temperatures reach 205F (96C).

The Senju Model RC-RES has a 3.7 K-Factor and installs with 1/2" (12.7 mm) National Pipe Thread (NPT), used in fire sprinkler systems throughout the United States. This Residential Fast Response Fire Sprinkler features a copper alloy body, phosphor bronze deflector, and PTFE gasket.

To order the Senju RC-RES with custom cover plates, contact us at 888.361.6662 or fill our our contact form.

 

With a maximum working pressure of 175 PSI (12.1 BAR), this pendent sprinkler hangs from above-ceiling piping behind a decorative cover plate and may be installed and used in accordance with NFPA 13, NFPA 13R, NFPA 13D and local fire code. Each Model RC-RES sprinkler is made by Senju, Japan's largest manufacturer of fire-suppression products.

This product is UL-listed, and appropriate for use in fire protection systems when accepted by the authority having jurisdiction.

 