Socket x Socket x FNPT CPVC Tee Adapter | 1" Runs x 1/2" FNPT Outlet

SKU
TCPVCTRT331
Socket x Socket x FNPT CPVC Tee Adapter has a 1" run, another 1" run, and a 1/2" outlet, allowing for the installation of a fire sprinkler head at a 90-degree angle to the pipe. Ideal for NFPA 13, NFPA 13D, and NFPA 13R fire sprinkler systems. Made in the USA!
$6.35
SKURun 1 Nominal DiameterRun 2 Nominal DiameterOutlet Nominal Diameter
TCPVCTRT331 1" CPVC Socket 1" CPVC Socket 1/2" FNPT
DesignMaterialWorking PressureTemperature Range
Socket x Socket x FNPT Tee Adapter Chlorinated Polyvinyl Chloride (CPVC) with Brass FNPT Insert 175 PSI at 150F (65C) 35F to 150F (2C to 65C)
ListingsThermafit Industries Part NumberAvailability
UL-Listed and FM-Approved. UL listed for Light Hazard Occupancies (NFPA 13) and Residential & Home Fire Sprinkler Systems (NFPA 13D, NFPA 13R) CPT-1112B Usually Ships Within 48 Hours

Product Description

Socket x Socket x FNPT CPVC Tee Adapter is a corrosion-resistant CPVC thermoplastic fitting for use with fire sprinkler pipe. This CPVC tee adapter features two CPVC socket runs and a FNPT brass outlet. This tee has a 1" run, another 1" run, and a 1/2" outlet, allowing for the installation of a fire sprinkler head at a 90-degree angle to the pipe.

This tee is designed to slide over CPVC pipe and fix permanently using an approved adhesive. Each Socket x Socket x FNPT CPVC Tee Adapter is made in the USA by Thermafit Industries, Inc., a California-based manufacturer of plumbing and fire sprinkler pipe fittings. This tee adapter has a working pressure rating of 175 PSI at 150F (65C) and is suitable for installation in NFPA 13, NFPA 13D, and NFPA 13R systems where allowed by state and local law.

Socket x Socket x FNPT CPVC Tee Adapter is intended for use in light hazard NFPA 13 occupancies, residential NFPA 13R occupancies, and home fire sprinkler systems in accordance with NFPA 13D. This product is UL-listed for use in wet-pipe automatic fire sprinkler systems in combination with UL-listed CPVC products.

Socket x Socket x FNPT CPVC Tee Adapter is backed by Thermafit's ten-year warranty from the date of shipment. To find Thermafit-approved CPVC glue, click here. Consult Thermafit's installation manual for minimum curing times, a full list of compatible adhesives, and friction loss allowances. Not suitable for outdoor installation.

Dimensions

CPVC Tee Adapter Dimensions

  • A: 1.325"
  • B: 1.310"
  • C: 0.875" (Schedule 40) or 1.125" (Schedule 80)
  • G: 2.186"
  • H: 1.556"
  • L: 3.112"
  • M: 1.695"
  • M1: 1.339"

Technical Documents

Click here to view the manual for this Socket x Socket x FNPT CPVC Tee Adapter.