System Sensor's PSP1 Special Purpose Plug-in Supervisory Switch monitors ball, angle, and non-rising stem gate valves for tampering and closure. UL & FM approved with a rain-tight die-cast iron enclosure and a waterproof actuating cord.
$199.99
  • Buy 2 for $189.99 each and save 5%
  • Buy 5 for $179.99 each and save 10%
  • Buy 10 for $169.99 each and save 15%
Part NumberMountingUL Rated Temperature RangeOperating Temperature Range
ELSSPSP1 Metal Bracket for Non-Rising Stem Gate Valves and Angle Valves 32F to 120F (0C to 49C) -4F to 149F (-20C to 65C)
Dimensions with BracketCableEnclosure RatingWarranty
8 1/2" L x 3" W x 2 1/2" D (21.5 cm x 7.5 cm x 5.6 cm) 8 feet (2.4 m) Long 2-Wire 18-Gauge Waterproof NEMA 3 UL Indoor/Outdoor Rated 3 Years
AvailabilityListings
Usually ships within 48 hours UL, ULC, FM, MEA, CA Fire Marshall

Product Description

System Sensor's PSP1 Special Purpose Plug-in Supervisory Switch is designed for applications where no other type of listed valve supervisory switch can be installed. This Special-Purpose Tamper Switch mounts to non-rising stem gate valves, ball valves, and angle valves in water-based systems, including fire sprinkler and standpipe systems.

System Sensor's PSP1 Special Purpose Plug-in Supervisory Switch prevents valve tampering and unwanted valve closure by activating a nearby alarm or fire alarm control panel using a supervisory cord. The waterproof cable threads through the valve's handwheel. When the handwheel rotates, the cord pulls out, closing a set of open contacts on the Special-Purpose Tamper Switch.

Featuring a rain-tight die-cast metal housing and approvals from UL, ULC, FM, MEA, and California's Office of the State Fire Marshal, System Sensor's rugged PSP Special Purpose Supervisory Switch is designed for indoor or outdoor use.

Each Special-Purpose Tamper Switch includes tamper-resistant screws, a security wrench, and a NEMA 3 rated enclosure. System Sensor's PSP1 Special Purpose Plug-in Supervisory Switch features a 360-degree mounting design and an adjustable-length cord for ease of installation and operation.

Additional Specifications

Specifications 
Shipping Weight 1.7 lbs. (0.8 kgs)
Operating Voltage 6/12/24V AC/DC
Maximum Operating Current 250 mA
Cover Tamper Switch Standard
US Patent Number 6,037,687