Tyco® TY3551 Concealed Pendent Sprinkler | SR | 5.6K | 155F | 51-790-1-155

SKU:
TY3551CP155
Manufacturer Part Number:
51-790-1-155

No reviews yet Write a Review
$28.99

Tyco® TY3551 Concealed Pendent | 155F | 51-790-1-155 | Hero

Tyco® TY3551 Concealed Pendent | 155F | 51-790-1-155 | Hero
Tyco® TY3551 Concealed Pendent | 155F | 51-790-1-155 | With Cover
Tyco® TY3551 Concealed Pendent | 155F | 51-790-1-155 | Deflector
Play Button
  • Tyco® RFII Cover Plate | Signal White | 139F | QRFS | Hero

  • Buy 100 - 199 and get 3% off
  • Buy 200 or above and get 7% off

Frequently Bought Together:

Tyco® TY3551 Concealed Pendent | 155F | 51-790-1-155 | Hero
Inc. Tax
Ex. Tax
Overview

Tyco RFII (TY3551) Standard Response Concealed Pendent Fire Sprinkler

This Tyco RFII Concealed Pendent fire sprinkler features a glass bulb activating at 155F (68C) with a 5.6 K-Factor, and 1/2 in. NPT threads. Each concealed pendent sprinkler head features a bronze frame and deflector. This sprinkler was designed to be covered by a Tyco RFII cover plate, allowing for optimal aesthetics and proper function. The manufacturer part number is 51-790-1-155 and the Sprinkler Identification Number (SIN) is TY3551.

The RFII Sprinkler delivers decorative, affordable defense against fire. Using a heat-activated glass bulb assembly, this automatic fire sprinkler opens when ambient temperatures reach 155F (68C), drenching the area surrounding a fire to keep it in its place of origin. This model has a 5.6 K-factor. These sprinklers are optimal for architecturally sensi­tive areas such as hotel lobbies, office buildings, churches, and restaurants.

Tyco RFII (TY3551) Standard Response Concealed Fire Sprinkler Head Listings and Approvals

Each RFII sprinkler is made by Tyco, a global leader in fire-suppression products. This concealed fire sprinkler head maintains UL Listing and is FM Approved as Standard Response.

The TY3551 is a commercial sprinkler and is cULus listed for use when installed in accordance with NFPA 13 requirements for wet pipe sprinkler systems and designed for use in commercial areas. This concealed pendent sprinkler head has a maximum working pressure of 175 PSI (12.1 BAR) UL Listed and connects to ceiling wet piping systems.

Tyco RFII (TY3551) Standard Response Concealed Pendent Head Sprinkler Installation and Other Information

During installation be aware that over tightening will cause permanent damage to the 1/2 in. NPT threads and/or the fire sprinklers themselves. Use the manufacturer approved installation wrench and tighten to a maximum torque of 14 ft-lb (19 N-m). Refer to the data sheet for additional storage and installation information.

This concealed sprinkler head is available at a temperature of 155 (68C) or 200F (93C) and must be paired with a Tyco RFII Cover Plate. These 139F (59C) cover plates come in a variety of finishes: Grey White, Brushed Brass, Brass, Signal White, Jet Black, Terra Brown, Brushed Chrome, and Polished Chrome. To choose your cover plate, find the “Options” section at the top of this product page.

Along with the required Cover Plate, TY3551 listed accessories include the RFII sprinkler wrench, manufacturer part number (56-000-1-075) and the Tyco Air and Dust Seal, manufacturer part number (56-908-1-001). This sprinkler head is commonly purchased with fire sprinkler shut off tools. These products are available in the “Frequently bought together” products section at the top of this product page.

Specifications
QRFS SKU:
TY3551CP155
Manufacturer Part Number:
51-790-1-155
Manufacturer:
Tyco
SIN:
TY3551
Model:
RFII
Head Type:
Concealed Pendent
Size:
1/2 in.
Size Detail:
1/2 in. NPT Sprinkler
K Factor:
5.6K
Response Type:
Standard Response (SR)
Temperature:
155F
Heat Element:
Glass Bulb
Coverage:
Standard Coverage
Material:
Bronze Frame, Bronze Deflector
Corrosion Resistant:
No
May Contain Lead:
Yes
UL Listed:
Yes
FM Approved:
Yes
Maximum Working Water Pressure:
175 PSI (UL, FM) 250 PSI (UL)
Length:
3.25 in. (82.55 mm)
Width:
3.25 in. (82.55 mm)
Height:
2.94 in. (74.68 mm)
Weight:
0.4 lb. (0.18 kg)
Available Box/Pack Quantity:
100
Finish:
Brass
Reviews
No reviews yet