Need a replacement fire sprinkler system part? Our trained staff will help you find the right part, the first time. Call us at 888-361-6662.

Tyco Escutcheon | Style 30 | Recessed | 3/4 in. Sprinkler | Chrome | 56-705-9-011

SKU
TY075RES30CH
With 1/2″ of adjustment and a 2-7/8″ outer ring, Tyco’s Chrome Style 30 Recessed Fire Sprinkler Escutcheon covers the gap between a sprinkler head and the ceiling. Combine this chrome escutcheon with select sprinklers from Star, Gem, Central, or Tyco to form a listed, recessed sprinkler assembly.
$4.23
SKU Finish Thread
TY075RES30CH Chrome 3/4″ (19mm) NPT
Adjustment Outer Cup Diameter Depth of Outer Cup
1/2″ (13 mm) 2-7/8″ (73 mm) 13/16″ (20mm)
Tyco Part No. Approvals & Listings Availability
56-705-9-011 UL, C-UL, FM* Usually Ships Within 48 Hours

Tyco Chrome Style 30 Recessed Escutcheon for 3/4″ NPT Fire Sprinklers

Tyco’s Chrome Style 30 Recessed Fire Sprinkler Escutcheon covers the gap between a sprinkler head and the ceiling, providing a smooth, aesthetically pleasing appearance. Tyco’s Style 30 escutcheon combines with select sprinkler heads to form a listed sprinkler assembly. These assemblies prevent smoke and heat from bypassing the heat-sensitive components of a fire sprinkler, helping them to activate at the proper time.

This recessed, two-piece escutcheon plate is tailored to provide a low-profile and decorative installation for 3/4″ NPT recessed pendent and horizontal sidewall sprinklers manufactured by Tyco and Central. The Tyco Style 30 Fire Sprinkler Escutcheon also offers 1/2″ of adjustment for ease of installation.

Will this escutcheon fit my sprinkler system?

Escutcheons are available in several finishes, sizes, and styles. The Tyco Style 30 Recessed Escutcheon is available from QRFS in a chrome or white finish, and may be installed as part of a listed sprinkler assembly with Tyco-brand sprinklers having the following sprinkler identification numbers (SINs):

  • TY4111
  • TY4131
  • TY4232
  • TY4234
  • TY4332
  • TY5137
  • TY6237

In addition, these escutcheons also replace Central 4221 escutcheons, Gem F705 escutcheons (for 3/4″ fire sprinklers), and Star 2086 escutcheons.

Contractors looking for more adjustment should consider a white Style 40 or chrome Style 40 escutcheon, which offer 3/4″ of adjustment to nearly all of these sprinklers (and more). Installing a Style 30 escutcheon with either of these sprinklers allows those sprinklers to retain their listings and approvals from UL, cUL, and FM.

More Information
Escutcheon Type Recessed
Escutcheon Fits Sprinkler Connection Size 3/4"
Escutcheon Finish Chrome
Escutcheon Retrofit No
Escutcheon Adjustable Yes
Escutcheon Adjustment 1/2"
Write Your Own Review
You're reviewing:Tyco Escutcheon | Style 30 | Recessed | 3/4 in. Sprinkler | Chrome | 56-705-9-011
Your Rating