Viking® VK494 Concealed Pendent Sprinkler | Residential | 4.9K | 155F | 23707AB

SKU:
VK494CP155
Manufacturer Part Number:
23707AB

No reviews yet Write a Review
$23.00

Viking® VK494 Concealed Pendent Sprinkler | Residential | 4.9K | 155F | 23707AB | QRFS | Hero

Viking® VK494 Concealed Pendent Sprinkler | Residential | 4.9K | 155F | 23707AB | QRFS | Hero
Viking® VK494 Concealed Pendent Sprinkler | Residential | 4.9K | 155F | 23707AB | QRFS | With Cover
  • Viking® Mirage Cover Plate | Brushed Brass | 135F | 3-5/16 in. OD | QRFS | Hero
  • Viking® Mirage Cover Plate | Black | 135F | 3-5/16 in. OD | QRFS | Hero
  • Viking® Mirage Cover Plate | Brushed Chrome | 135F | 3-5/16 in. OD | QRFS | Hero
  • Viking® Mirage Cover Plate | Ivory | 135F | 3-5/16 in. OD | QRFS | Hero
  • Viking® Mirage Cover Plate | Antique Brass | 135F | 3-5/16 in. OD | QRFS | Hero
  • Viking® Mirage Cover Plate | Polished Chrome | 135F | 3-5/16 in. OD | QRFS | Hero
  • Viking® Mirage Cover Plate | Brushed Copper | 135F | 3-5/16 in. OD | QRFS | Hero
  • Viking® Mirage Cover Plate | White | 135F | 3-5/16 in. OD | QRFS | Hero
  • Viking® Mirage Cover Plate | Bright Brass| 135F | 3-5/16 in. OD | QRFS | Hero
  • Viking® Mirage Cleanroom Cover Plate | Chrome | 135F | QRFS | Hero
  • Viking® Mirage Cleanroom Cover Plate | White | 135F | QRFS | Hero
  • Viking® Mirage Cover Plate | Black | 135F | 2-3/4 in. OD | QRFS | Hero
  • Viking® Mirage Cover Plate | Polished Chrome | 135F | 2-3/4 in. OD | QRFS | Hero
  • Viking® Mirage Cover Plate | Ivory | 135F | 2-3/4 in. OD | QRFS | Hero
  • Viking® Mirage Cover Plate | Bright Brass | 135F | 2-3/4 in. OD | QRFS | Hero
  • Viking® Mirage Cover Plate | White | 135F | 2-3/4 in. OD | QRFS | Hero
  • Viking® Mirage Cover Plate | Brushed Chrome | 135F | 2-3/4 in. OD | QRFS | Hero
  • Viking® Mirage Cover Plate | Antique Brass | 135F | 2-3/4 in. OD | QRFS | Hero
  • Viking® Mirage Cover Plate | Brushed Brass | 135F | 2-3/4 in. OD | QRFS | Hero
  • Viking® Mirage Cover Plate | Brushed Copper | 135F | 2-3/4 in. OD | QRFS | Hero

  • Buy 50 - 99 and get 3% off
  • Buy 100 or above and get 7% off

Frequently Bought Together:

Viking® VK494 Concealed Pendent Sprinkler | Residential | 4.9K | 155F | 23707AB | QRFS | Hero
Inc. Tax
Ex. Tax
Overview

Viking Freedom Residential Concealed Pendent (VK494) Fire Sprinkler Head

This Viking Freedom Residential Concealed Pendent Fire Sprinkler features a glass bulb activating at 155F (68C) with a 4.9 K-Factor, and 1/2 in. NPT threads. Each concealed pendent head features a brass body and bronze deflector. The Sprinkler Identification Number (SIN) is VK494. This is a residential response, standard coverage sprinkler with a maximum working water pressure of 175 PSI.

The VK494 concealed pendent fire sprinkler delivers effective, affordable defense in residential occupancies, such as apartment, hotel, or house fire sprinkler systems. Using a heat-activated glass bulb assembly, this automatic fire sprinkler opens when ambient temperatures reach 155F (68C), drenching the area surrounding a fire to keep it in its place of origin. For concealed application, refer to data sheet for installation instructions with the approved Viking cover(s).

Viking Residential Concealed Freedom Fire Sprinkler (VK494) Sprinkler Head Listings and Approvals

Each Freedom Concealed Pendent sprinkler is made by Viking, a global leader in fire protection manufacturing for nearly 100 years. When installed properly, this fire sprinkler head maintains listings and approvals from cULus (Category VKKW). Refer to the datasheet for listings and approvals in specific temperatures and/or applications.

When using Viking Residential Concealed Pendent Sprinkler VK494 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of coverage and minimum water supply requirements shown in the Approval Chart in the datasheet. This concealed pendent head has a maximum working pressure of 175 PSI (12.1 BAR) UL and connects to wet piping systems.

Viking Freedom Residential Concealed Pendent (VK494) Sprinkler Installation and Other Information

During installation be aware that over tightening will cause permanent damage to the 1/2 in. NPT threads and/or the fire sprinklers themselves. Use the manufacturer approved installation wrench and tighten to a maximum torque of 14 ft-lb (19 N-m). Refer to the data sheet for additional storage and installation information.

This residential concealed pendent sprinkler is available at a 155F (68C) and 200F (93C), temperature. To select your temperature, visit the “Options” section at the top of this product page. Additionally, use the Cover Plate option to select a Cover Plate finish and temperature.

The VK494 listed accessories include the approved Viking Wrench (part no. 24339), the Viking cap removal tool (part no. 24340), the cover plate installation tool(s) for large and small diameter covers (part no. 14412, 14867), and the approved Viking Cover(s) (part no. 23190, 23174), which are available in two diameters and a variety of finishes. Commonly purchased with fire sprinkler head cabinets and sprinkler shut off tools. These products are available in the “Frequently bought together” products section at the top of this product page.

Specifications
QRFS SKU:
VK494CP155
Manufacturer Part Number:
23707AB
Manufacturer:
Viking
SIN:
VK494
Model:
Freedom
Head Type:
Concealed Pendent
Size:
1/2 in.
Size Detail:
1/2 in. NPT Sprinkler
K Factor:
4.9K
Response Type:
Residential
Temperature:
155F
Heat Element:
Glass Bulb
Coverage:
Standard Coverage
Material:
Brass Body, Bronze Deflector
Corrosion Resistant:
No
May Contain Lead:
Yes
UL Listed:
Yes
FM Approved:
No
Maximum Working Water Pressure:
175 PSI
Length:
2.25 in. (57.15 mm)
Width:
2.25 in. (57.15 mm)
Height:
3.25 in. (82.55 mm)
Weight:
0.38 lb. (0.17 kg)
Available Box/Pack Quantity:
50
Finish:
Brass