Viking Fire Sprinkler 5.6K Brass Pendent QR 155F | VK3001

SKU
VK3001BR155
Viking VK3001 Quick Response Brass Pendent Fire Sprinkler activates at 155F (68C) to defend light and ordinary hazard commercial occupancies against fire. This UL & FM approved fire sprinkler features a 5.6K orifice and a 1/2" (15 mm BSP) NPT connection.
$8.95
Part NumberConstructionConnectionOrifice
VK3001BR155 Brass Finish, Brass Frame, And Brass Deflector 1/2" (15 mm BSP) NPT 5.6K
Temperature RatingMaximum Working PressureApprovals and ListingsAvailability
155F (68C) 175 PSI (12.1 BAR) cULus, FM Usually ships within 48 hours

Product Description

Viking VK3001 Quick Response Brass Pendent Fire Sprinkler delivers powerful, affordable fire suppression in light and ordinary hazard commercial occupancies such as universities, auditoriums, churches, and parking garages. Using a heat-activated 3mm glass bulb, this automatic fire sprinkler opens when ambient temperatures reach 155F (68C), supporting rescue and evacuation efforts by lowering ambient temperatures.

The Viking Model VK3001 has a 5.6 K-Factor and installs with 1/2" (15 mm BSP) National Pipe Thread (NPT), used in fire sprinkler systems throughout the United States. This Quick Response Fire Sprinkler features a brass finish, brass frame, brass screw, stainless steel deflector, and a nickel alloy spring.

With a discharge temperature of 155F (68C), these sprinklers activate early enough to provide robust protection to people and property while reducing the risk of accidental discharge. 155F (68C) Quick Response Fire Sprinklers are preferred for use in cafeterias, auditoriums, convention centers and other gathering spaces where human safety is the first priority. The Viking Model VK3001 is a multi-purpose head suitable for use in covered horse stables, canneries, and many industrial applications.

With a maximum working pressure of 175 PSI (12.1 BAR), this pendent sprinkler hangs from above-ceiling piping and may be installed and used in accordance with NFPA 13 and local fire code. Each Model VK3001 sprinkler is made by Viking, a global leader in fire protection manufacturing for nearly 100 years.

This product is UL & FM approved, and appropriate for use in fire protection systems when accepted by the authority having jurisdiction. In accordance with NFPA 13, a higher temperature rating may be required when installing a quick response fire sprinkler in or near heat sources, unventilated spaces, uncovered steam mains, or uninsulated rooftops.

Technical Documents

Click here to view the data sheet for the Viking VK3001 Quick Response Brass Pendent Fire Sprinkler.