QRFS.com is open and fulfilling orders. Read our Emergency Preparedness Guide.

Viking Fire Sprinkler 5.6K White Horizontal Sidewall QR 155F | VK305

SKU
VK305WH155
Viking VK305 Quick Response White Horizontal Sidewall Fire Sprinkler activates at 155F (68C) to defend ordinary hazard commercial occupancies against fire. This UL & FM approved fire sprinkler features a 5.6K orifice and a 1/2" (12.7 mm) NPT connection.
$12.95
  • Buy 50 for $12.04 each and save 7%
  • Buy 100 for $11.40 each and save 12%
  • Buy 500 for $10.75 each and save 17%
Part NumberConstructionConnectionOrifice
VK305WH155White Finish, Brass Frame, And Copper Deflector1/2" (12.7 mm) NPT5.6K
Temperature RatingMaximum Working PressureApprovals and ListingsAvailability
155F (68C)175 PSI (12.1 BAR)cULus, FM, CCCFIn Stock

Product Description

Viking VK305 Quick Response White Horizontal Sidewall Fire Sprinkler delivers powerful, affordable fire suppression in ordinary hazard commercial occupancies such as universities, auditoriums, churches, and parking garages. Using a heat-activated 3mm glass bulb, this automatic fire sprinkler opens when ambient temperatures reach 155F (68C), supporting rescue and evacuation efforts by lowering ambient temperatures.

The Viking Model VK305 has a 5.6 K-Factor and installs with 1/2" (12.7 mm) National Pipe Thread (NPT), used in fire sprinkler systems throughout the United States. This Quick Response Fire Sprinkler features a white finish, brass frame, brass screw, copper deflector, and a spring sealing assembly made with nickel alloy and PTFE tape.

With a discharge temperature of 155F (68C), these sprinklers activate early enough to provide robust protection to people and property while reducing the risk of accidental discharge. 155F (68C) Quick Response Fire Sprinklers are preferred for use in cafeterias, auditoriums, convention centers and other gathering spaces where human safety is the first priority. The Viking Model VK305 is a multi-purpose head suitable for use in covered horse stables, canneries, and many industrial applications.

With a maximum working pressure of 175 PSI (12.1 BAR), this horizontal sidewall sprinkler installs on a wall or the side of a beam where ceiling piping is not desirable and may be installed and used in accordance with NFPA 13 and local fire code. Each Model VK305 sprinkler is made by Viking, a global leader in fire protection manufacturing for nearly 100 years.

This product is UL & FM approved for use in fire protection systems when accepted by the authority having jurisdiction. In accordance with NFPA 13, a higher temperature rating may be required when installing a quick response fire sprinkler in or near heat sources, unventilated spaces, uncovered steam mains, or uninsulated rooftops.

Technical Documents

Click here to view the data sheet for the Viking VK305 Quick Response White Horizontal Sidewall Fire Sprinkler.

Write Your Own Review
You're reviewing:Viking Fire Sprinkler 5.6K White Horizontal Sidewall QR 155F | VK305
Your Rating