Viking Fire Sprinkler Wrench | Coated, Recessed, & Domed ELO Heads | 3/4″ NPT | 11663W/B

SKU
VKCSWA
Viking Sprinkler Head Wrench makes it easy to install Viking-brand coated, recessed, and domed ELO (extra large orifice) fire sprinklers. Compatible with the VK534, VK537, VK608, and the VK 617, the #11663W/B socket minimizes slippage and rotates fire sprinklers using a 1/2″ ratchet (not included).
$115.95
SKU Material Viking Part Number
VKCSWA Black-Finished Metal 11663W/B
Compatible Sprinklers Availability
VK534, VK537, VK608, & VK 617 (3/4″ NPT) Usually Ships Within 48 Hours

Viking Sprinkler Head Wrench for Coated, Recessed, and Domed ELO Fire Sprinklers (11663W/B)

Viking Sprinkler Head Wrench 11663W/B is a specialized fire sprinkler installation tool for use with select Viking Microfast® Model M ELO (extra large orifice) fire sprinklers. When paired with a 1/2″ ratchet (not included), this socket can quickly and safely secure wax-coated, recessed, and domed concealed heads.

Who needs a fire sprinkler wrench?

Fire sprinkler wrenches allow contractors to install heads easily—and without damaging the heads themselves. NFPA 13 also requires building owners to keep anywhere from 6 to 24 spare sprinkler heads on-site, as well as a supply of corresponding sprinkler head wrenches. Adhering to this requirement ensures that all necessary components are ready and available for the immediate removal and replacement of faulty or activated sprinkler heads.

Is this wrench compatible with my sprinkler head?

Viking Sprinkler Head Wrench provides the leverage needed to install wax-coated, domed concealed, or recessed ELO fire sprinklers, including those with the following sprinkler identification numbers (SINs):

  • VK534
  • VK537
  • VK608
  • VK617

How do I use the sprinkler head wrench?

Wax-coated, recessed, and domed concealed fire sprinklers each install differently. Follow the instructions provided in the datasheets for your specific Viking-brand model. In general, installation takes the following steps:

  1. Leave the protective orange shield on the fire sprinkler’s deflector.
  2. Gently slide the wrench head around the sprinkler’s body. Make sure that the wrench head grips the “wrench flats”—the section of the sprinkler’s frame shaped to fit neatly inside the wrench.
  3. Twist the ratchet until finger-tight and secure with an additional 1 to 1 1/2 turns.

Microfast® is a registered trademark of The Viking Corporation