Viking FREEDOM Residential Fire Sprinkler 5.8K White Horizontal Sidewall 155F | VK460

SKU
VK460WH155
Viking VK460 Residential Fast Response White Horizontal Sidewall Fire Sprinkler activates at 155F (68C) to defend ordinary hazard residential occupancies against fire. This UL listed fire sprinkler features a 5.8K orifice and a 1/2" (15 mm BSP) NPT connection.
$19.99
Part NumberConstructionConnectionOrifice
VK460WH155 White Finish, Brass Frame, And Brass Or Phosophor Bronze Deflector 1/2" (15 mm BSP) NPT 5.8K
Temperature RatingMaximum Working PressureApprovals and ListingsAvailability
155F (68C) 175 PSI (12.1 BAR) cULus, VdS Usually ships within 48 hours

Product Description

Viking VK460 Residential Fast Response White Horizontal Sidewall Fire Sprinkler delivers trustworthy fire suppression in ordinary hazard residential occupancies such as homes, apartments, dormitories, and hotels. Using a heat-activated 3mm glass bulb, this automatic fire sprinkler opens when ambient temperatures reach 155F (68C), supporting rescue and evacuation efforts by lowering ambient temperatures. Designed for residential applications, the 5.8K orifice makes efficient use of available water supplies in residential sprinkler systems.

The Viking Model VK460 has a 5.8 K-Factor and installs with 1/2" (15 mm BSP) National Pipe Thread (NPT), used in fire sprinkler systems throughout the United States. This Residential Fast Response Fire Sprinkler features a white finish, brass frame, stainless steel compression screw, brass or phosphor bronze deflector, and a spring sealing assembly made with nickel alloy and PTFE tape.

This 155F (68C) temperature rating strikes a balance between a fire sprinkler that activates too soon, causing accidental discharge, and too late. 155F (68C) Residential Fast Response Fire Sprinklers can be installed to wet and dry pipe fire sprinkler systems, and are preferred for use in one and two-family dwellings, apartments, duplexes, and boarding houses. The Viking Model VK460 is also a suitable choice for installation in many college dormitories, condominiums, and nursing homes.

With a maximum working pressure of 175 PSI (12.1 BAR), this horizontal sidewall sprinkler installs on a wall or the side of a beam where ceiling piping is not desirable and may be installed and used in accordance with NFPA 13, NFPA 13R, NFPA 13D and local fire code. Each Model VK460 sprinkler is made by Viking, a global leader in fire protection manufacturing for nearly 100 years.

This product is UL listed, and appropriate for use in fire protection systems when accepted by the authority having jurisdiction. In accordance with NFPA 13, a higher temperature rating may be required when installing a residential fast response fire sprinkler in or near heat sources, unventilated spaces, uncovered steam mains, or uninsulated rooftops.

Technical Documents

Click here to view the data sheet for the Viking VK460 Residential Fast Response White Horizontal Sidewall Fire Sprinkler.