Viking® Domed Sidewall Cover Plate | White Painted | 135F | 3-1/8 in. OD | 13501MA/W

SKU:
11-VK-13501-WH135
Manufacturer Part Number:
13501MA/W

No reviews yet Write a Review
$26.75

Viking® Domed Sidewall Cover Plate | White 135F | QRFS | Hero

Viking® Domed Sidewall Cover Plate | White 135F | QRFS | Hero
Viking® Domed Sidewall Cover Plate | White 135F | QRFS | Label
Viking® Domed Sidewall Cover Plate | White 135F | QRFS | Family
Play Button

  • Buy 50 - 399 and get 2.5% off
  • Buy 400 or above and get 7.5% off

Frequently Bought Together:

Viking® Domed Sidewall Cover Plate | White 135F | QRFS | Hero
Inc. Tax
Ex. Tax
Overview

Viking Domed Sidewall Fire Sprinkler Cover Plate

Viking Domed Sidewall (Label No: 13584A) White Fire Sprinkler Cover Plate with 135F (57C) activation temperature. This fire sprinkler cover works with certain Viking pendent fire sprinklers, including certain dry pendents.  The Domed Sidewall cover facilitates timely activation of these Viking fire sprinkler heads with a temperature rating of 135F (57C) or 165F (74C). The outer diameter of this cover is 3-1/8 in. This Viking cover plate is available with a 1/2 in. adjustment.

The Viking Domed Sidewall cover plate is a cover plate used with compatible sidewall sprinklers.  It provides a push-on connection into the sprinklers cup. This cover plate is available in four finishes. These finishes include Painted White, Polished Chrome, Ivory Painted, and Black Painted.  Along with these base finishes, for an additional fee Viking will custom paint this cover in any finish you prefer. Contact QRFS customer support for more details.

Viking Domed Sidewall Cover Plate Sprinkler Head Compatibility and Listings

This Sprinkler Head Cover Plate from Viking may be listed by UL, FM, and/or other organizations depending on the sprinkler it’s being used with. It meets the requirements of a sprinkler assembly per NFPA 13, where approved by the local Authority Having Jurisdiction. It installs by simply pushing the cover into the sprinkler’s frame, and can be adjusted up to 1/2 in. The recommended hole diameter when installing sprinkler heads using this cover is 2-5/8 in.

To remove your existing cover plate, gently twist the cover to the left while applying downward pressure by pulling gently as you turn.

When this fire sprinkler cover plate reaches its specified temperature of 135F (57C) or 165 (74C) the solder holding the plate's decorative exterior on the frame melts, and the two separate. For many cover plates, the rated temperature is at least 20F (6.7C) cooler than the sprinkler head's activation temperature, which ensures that the cover plate detaches early enough to allow the sprinkler to activate on time. However, each manufacturer's product line varies slightly, and cover plate temperatures may be closer to or further away from the fire sprinkler's activation temperature. Use only the cover plate approved by the manufacturer for your specific sprinkler.

Viking Domed Sidewall Cover Plate Finishes, Temperatures, and Listed Accessories

These Viking Sidewall fire sprinkler cover domes are available in Painted White, Polished Chrome, Ivory Painted, and Black Painted. It is available at a temperature of 135F (57C) or 165F (74C). You can choose from all the available options by selecting from the dropdown at the top of the page. Find all related products in the Frequently Bought Together section above.

Viking is a leader in the fire protection manufacturing industry, with a variety of sprinkler heads, escutcheons, and cover plates.

This Sprinkler Cover Plate fits the following Viking concealed sprinkler heads:

  • VK630
  • VK631
Specifications
QRFS SKU:
11-VK-13501-WH135
Manufacturer Part Number:
13501MA/W
Manufacturer:
Viking
Model:
Domed Sidewall
Label Number:
13584A
Installation Type:
Push On
Adjustment:
1/2 in.
Outer Diameter:
3-1/8 in.
Inner Diameter:
2-3/8 in.
Finish:
White
Finish Detail:
White Painted
Temperature:
135F
Corrosion Resistant:
No
UL Listed:
Yes
FM Approved:
No
Length:
3.13 in. (79.5 mm)
Width:
3.13 in. (79.5 mm)
Height:
1.75 in. (44.45 mm)
Weight:
0.21 lb. (0.1 kg)
Available Box/Pack Quantity:
50
Reviews
No reviews yet