QRFS.com is open and fulfilling orders. Read our Emergency Preparedness Guide.

Viking FREEDOM Residential Fire Sprinkler 4.0K Concealed Horizontal Sidewall 165F | VK4800 - Lead Free!

SKU
VK4800CS165
Viking VK4800 Residential Fast Response Concealed Horizontal Sidewall Fire Sprinkler activates at 165F (74C) to defend ordinary hazard residential occupancies against fire. This UL-listed fire sprinkler features a 4.0K orifice and a 1/2" (12.7 mm) NPT connection.
$79.95
  • Buy 50 for $74.35 each and save 7%
  • Buy 100 for $70.36 each and save 12%
  • Buy 500 for $66.36 each and save 17%
Part NumberConstructionConnectionOrifice
VK4800CS165Brass Body And Brass Deflector Ring1/2" (12.7 mm) NPT4.0K
Temperature RatingApprovalsCover Plate Activation TemperatureCover Plate Finish
165F (74C)cULus, NYC135F (57C)Choice of White, Ivory, Black, Antique Brass, Brushed Brass, Brushed Chrome, Bright Brass, Polished Chrome, or Brushed Copper. Custom Finishes by Special Order.
Maximum Working PressureAvailability
175 PSI (12.1 BAR)Usually ships within 48 hours

Product Description

Viking V4800 Residential Fast Response Concealed Horizontal Sidewall Fire Sprinkler delivers decorative, competitively-priced defense against fire in ordinary hazard residential occupancies such as homes, apartments, dormitories, and hotels. Using a heat-activated soldered link and lever assembly, this automatic fire sprinkler opens when ambient temperatures reach 165F (74C), reducing the likelihood of flashover and facilitating safe evacuation.

The included low-profile cover plate mounts flush to nearby walls and is available in a custom finish by special order or in one nine standard finishes, including: white, ivory, black, antique brass, brushed brass, brushed chrome, bright brass, polished chrome, or brushed copper. When temperatures near the ceiling reach 135F (57C), the soldered cover plate detaches, exposing the head of the Viking VK4800 concealed horizontal sidewall fire sprinkler, which activates when temperatures reach 165F (68C).

The Viking Model V4800 has a 4.0 K-Factor and installs with 1/2" (12.7 mm) National Pipe Thread (NPT), used in fire sprinkler systems throughout the United States. This Residential Fast Response Fire Sprinkler features a lead-free design in compliance with the Reduction of Lead in Drinking Water Act, including a brass body, brass deflector ring, and a nickel-alloy sealing assembly with PFTE. This fire sprinkler features up to 1/4" (6.4 mm) of adjustment and includes a p.

To order the Viking V4800 with custom cover plates, contact us at 888.361.6662 or fill our our contact form.

With a maximum working pressure of 175 PSI (12.1 BAR), this horizontal sidewall sprinkler installs on a wall or the side of a beam where ceiling piping is not desirable and may be installed and used in accordance with NFPA 13, NFPA 13R, NFPA 13D and local fire code. Each Model V4800 sprinkler is made by Viking, a global leader in fire protection manufacturing for nearly 100 years.

This product is UL-listed, and appropriate for use in fire protection systems when accepted by the authority having jurisdiction.

Technical Documents

Click here to view the data sheet for the Viking V4800 Residential Fast Response Concealed Horizontal Sidewall Fire Sprinkler.

Write Your Own Review
You're reviewing:Viking FREEDOM Residential Fire Sprinkler 4.0K Concealed Horizontal Sidewall 165F | VK4800 - Lead Free!
Your Rating