Viking Residential Fire Sprinkler 4.2K Chrome Horizontal Sidewall 155F | VK484
- Buy 50 for $10.18 each and save 7%
- Buy 100 for $9.64 each and save 12%
- Buy 500 for $9.09 each and save 17%
Part Number | Construction | Connection | Orifice |
---|---|---|---|
VK484CH155 | Chrome Finish, Brass Frame, And Brass Deflector | 1/2" (12.7 mm) NPT | 4.2K |
Temperature Rating | Maximum Working Pressure | Approvals and Listings | Availability |
---|---|---|---|
155F (68C) | 155 PSI (10.7 BAR) | cULus, NYC | Usually ships within 48 hours |
Product Description
Viking VK484 Residential Fast Response Chrome Horizontal Sidewall Fire Sprinkler delivers powerful, affordable fire suppression in ordinary hazard residential occupancies such as homes, apartments, dormitories, and hotels. Using a heat-activated 3mm glass bulb, this automatic fire sprinkler opens when ambient temperatures reach 155F (68C), supporting rescue and evacuation efforts by lowering ambient temperatures. Designed for residential applications, the 4.2K orifice makes efficient use of available water supplies in smaller sprinkler systems.
Viking's Freedom Residential Pendent Sprinklers are designed to be unobtrusive, fast-acting, and capable of providing coverage of up to 16 feet by 20 feet (4.9 m x 6.1 m). Designed for residential applications, the 4.2K orifice makes efficient use of available water supplies in smaller sprinkler systems.
The Viking Model VK484 has a 4.2 K-Factor and installs with 1/2" (12.7 mm) National Pipe Thread (NPT), used in fire sprinkler systems throughout the United States. This Residential Fast Response Fire Sprinkler features a chrome finish, brass frame, brass screw, brass deflector, and a spring sealing assembly made with nickel alloy and PTFE tape.
This 155F (68C) temperature rating strikes a balance between a fire sprinkler that activates too soon, causing accidental discharge, and too late. 155F (68C) Residential Fast Response Fire Sprinklers can be installed to wet and dry pipe fire sprinkler systems, and are preferred for use in one and two-family dwellings, apartments, duplexes, and boarding houses. The Viking Model VK484 is also a suitable choice for installation in many college dormitories, condominiums, and nursing homes.
With a maximum working pressure of 155 PSI (10.7 BAR), this horizontal sidewall sprinkler installs on a wall or the side of a beam where ceiling piping is not desirable and may be installed and used in accordance with NFPA 13, NFPA 13R, NFPA 13D and local fire code. Each Model VK484 sprinkler is made by Viking, a global leader in fire protection manufacturing for nearly 100 years.
This product is UL-listed, and appropriate for use in fire protection systems when accepted by the authority having jurisdiction. In accordance with NFPA 13, a higher temperature rating may be required when installing a residential fast response fire sprinkler in or near heat sources, unventilated spaces, uncovered steam mains, or uninsulated rooftops.