Viking Sprinkler Head Wrench | Dry Concealed Sprinklers (Recessed & Domed) | 07565W/B

SKU
VKCSW0
Viking Sprinkler Head Wrench makes it easy to install select Viking-brand concealed dry fire sprinklers. Compatible with a variety of models, the #07565W/B socket minimizes slippage and rotates fire sprinklers using a 1/2″ ratchet (not included).
$115.95
SKU Material Viking Part Number
VKCSW0 Black-Finished Metal 07565W/B
Compatible Sprinklers Availability
See List Below Usually Ships Within 48 Hours

Viking Sprinkler Head Wrench for Recessed and Domed Concealed Dry Fire Sprinklers (07565W/B)

Viking Sprinkler Head Wrench 07565W/B is a specialized fire sprinkler installation tool for use with select Viking dry sprinkler heads. When paired with a 1/2″ ratchet (not included), this socket can quickly and safely secure more than ten commercial and residential fire sprinklers.

Who needs a fire sprinkler wrench?

Fire sprinkler wrenches allow contractors to install heads easily—and without damaging the heads themselves. NFPA 13 also requires building owners to keep anywhere from 6 to 24 spare sprinkler heads on-site, as well as a supply of corresponding sprinkler head wrenches. Adhering to this requirement ensures that all necessary components are ready and available for the immediate removal and replacement of faulty or activated sprinkler heads.

Is this wrench compatible with my sprinkler head?

This Viking Sprinkler Head Wrench provides the leverage needed to install a variety of concealed fire sprinklers, including those with the following sprinkler identification numbers (SINs):

  • VK158
  • VK161
  • VK162
  • VK164
  • VK169
  • VK180
  • VK181
  • VK182
  • VK186
  • VK188
  • VK190
  • VK192
  • VK194
  • VK196
  • VK2543
  • VK2793
  • VK290
  • VK2923

How do I use the sprinkler head wrench?

Always follow the instructions provided in the datasheet for your specific Viking-brand model. In general, installation takes the following steps:

  1. Remove the protective cap from the sprinkler head.
  2. Gently slide the wrench head around the sprinkler’s body. Make sure that the wrench head grips the “wrench flats”—the section of the sprinkler’s frame shaped to fit neatly inside the wrench.
  3. Twist the ratchet until the sprinkler head is firmly attached to the piping.