Need a replacement fire sprinkler system part? Our trained staff will help you find the right part, the first time. Call us at 888-361-6662.

6" (152.4 mm) Flow Switch - Waterflow Detector by System Sensor | UL & FM Approved!

SKU
WFD6
6" (152.4 mm) Flow Switch with 450 PSI pressure rating sounds the alarm during fire sprinkler system flows with a time delay to prevent false positives.
$164.50
  • Buy 2 for $156.28 each and save 5%
  • Buy 5 for $148.05 each and save 10%
  • Buy 10 for $139.83 each and save 15%
Part NumberSizeCompatible PipingTemperature Rating
WFD6 6" (152.4 mm) Schedule 10 to Schedule 40 32F to 150F (0C to 49C)
Overall DimensionsUL Pressure RatingTriggering Threshold Bandwidth Flow RateMaximum Surge
4.6"H x 9"W (116.8 mm x 228.6 mm) 450 PSI 4 Gallons to 10 Gallons Per Minute 18 Feet Per Second
Conduit EntranceEnclosure RatingWarrantyAvailability
Two (2) 1/2" Conduits (Open and Knockout Type) UL NEMA 4 3 Years Usually ships within 48 hours

Product Description


6" (152.4 mm) Flow Switch is designed to detect fire sprinkler activations and send an alarm to a fire alarm panel and/or local fire authorities when water flows through fire system piping. Manufactured by System Sensor, a global fire alarm systems expert, this 6" (152.4 mm) WFDN-Series Waterflow Detector is designed for indoor and outdoor use in commercial, residential and industrial water-based systems.

This 6" (152.4 mm) Flow Switch is suitable for high and low temperatures and installs either vertically or horizontally on piping from Schedule 10 to Schedule 40. The NEMA 4-rated enclosure insulates electrical components and resists corrosion while giving installers and inspectors a clear view of flow direction.

The built-in timer on each 6" (152.4 mm) Flow Switch delays alarm activation and reduces the number of false alarms caused by pressure surges or trapped air. Choosing a delay setting of up to 90 seconds is easy as turning the timer dial.

6" (152.4 mm) Flow Switch includes features that make installation and setup in low-light environments simple, including high-contrast pad-printed markings, set-by-feel timer tabs, and raised texured lettering. Tamper switch covers (sold separately) snap into place and UL-listed models of the 6" (152.4 mm) WFDN-Series Waterflow Detector feature tamper-resistant cover screws that prevent unauthorized entry.

Write Your Own Review
You're reviewing:6" (152.4 mm) Flow Switch - Waterflow Detector by System Sensor | UL & FM Approved!
Your Rating