Blazemaster CPVC Glue | One-Step Solvent Cement | 1 Pint

SKU:
51-BL-CMNTP
Manufacturer Part Number:
V5097P
$51.86

Select Variation

Shipping Restriction: This product cannot be shipped by air due to carrier restrictions. Ground shipping is the only available option.

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
UL Listed:
Not Required
Manufacturer:
BlazeMaster™

Blazemaster CPVC Glue | One-Step Solvent Cement | 1 Pint

Best Seller
Blazemaster CPVC Glue | One-Step Solvent Cement | 1 Pint
Blazemaster CPVC Glue | One-Step Solvent Cement | 1 Pint
Blazemaster CPVC Glue | One-Step Solvent Cement | 1 Pint
Blazemaster CPVC Glue | One-Step Solvent Cement | 1 Pint
Play Button
Overview

BlazeMaster CPVC Glue | One-Step Solvent Cement | 1 Pint

BlazeMaster CPVC One-Step Solvent Cement is a purpose-built adhesive formulated to join CPVC plastic pipe and fittings by solvent welding, creating a strong, permanent bond when used with proper cutting, deburring, dry-fitting, and assembly techniques. This red cement is commonly selected for CPVC piping work where a visible cement line helps confirm coverage during installation, and the one-step formulation is intended to simplify the joining process when allowed by the pipe/fitting manufacturer instructions and local code requirements. The 1-pint size is a practical, jobsite-friendly container for small to mid-size installs, service work, and repairs.

When applied correctly, the cement softens the CPVC surfaces and fuses the pipe and fitting together as the solvents flash off, resulting in a durable joint that supports long-term system reliability. For best results, use only on clean, dry CPVC components, apply an even coat to both the fitting socket and pipe end as appropriate, assemble immediately with a firm push and slight twist to fully seat the connection, and hold the joint briefly to reduce push-back. Cure times vary based on temperature, humidity, pipe size, and fit, so allow adequate set and cure time before pressure testing and placing the system into service, following the CPVC system instructions and the authority having jurisdiction.

Because this product contains flammable solvents, it must be used with good ventilation and kept away from heat, sparks, and open flames, and smoking should be avoided in the work area. Avoid breathing vapors and prevent contact with eyes and skin by wearing appropriate gloves and eye/face protection. Keep the container tightly closed when not in use, store in a cool, well-ventilated place, and keep out of reach of children. If a spill occurs, ventilate the area, remove ignition sources, and absorb with suitable inert material for proper disposal in accordance with local requirements.

This 1-pint BlazeMaster CPVC cement is a solid choice when you need a dependable CPVC solvent-weld adhesive with straightforward application and clear visual confirmation during installation, while still maintaining the jobsite safety controls required for solvent-based products.

Note: This product is restricted from air transport and must ship via Videos

-->
Reviews
No reviews yet
Product Alternatives