QRFS.com is open and fulfilling orders. Read our Emergency Preparedness Guide.

CPVC Straight Terminal Adapter | 3/4" Slip x 1/2" FNPT Outlet

SKU
TCPVCTA21

3/4" Slip x 1/2" FNPT CPVC Straight Terminal Adapter has a 3/4" slip inlet and a brass 1/2" FNPT connection, facilitating the installation of a fire sprinkler head. Ideal for NFPA 13, NFPA 13D, and NFPA 13R fire sprinkler systems. Made in the USA!

$3.25
SKUInlet DiameterOutlet DiameterDesign
TCPVCTA213/4" CPVC Socket1/2" National Pipe Thread (NPT)Slip x Threaded Straight Terminal Adapter
MaterialWorking PressureTemperature RangeListings
Chlorinated Polyvinyl Chloride (CPVC) with Brass FNPT Insert175 PSI at 150F (65C)35F to 150F (2C to 65C)UL-Listed and FM-Approved. UL listed for Light Hazard Occupancies (NFPA 13) and Residential & Home Fire Sprinkler Systems (NFPA 13D, NFPA 13R)
Thermafit Industries Part NumberAvailability
CPFHA-3412PUsually Ships Within 48 Hours

Product Description

3/4" Slip x 1/2" FNPT CPVC Straight Terminal Adapter is a corrosion-resistant CPVC thermoplastic fitting for use with fire sprinkler pipe. This CPVC straight terminal adapter has a 3/4" slip inlet and a brass 1/2" FNPT connection, facilitating the installation of a fire sprinkler head.

This straight adapter is designed to slide over CPVC pipe and fix permanently using an approved adhesive. Each 3/4" Slip x 1/2" FNPT CPVC Straight Terminal Adapter is made in the USA by Thermafit Industries, Inc., a California-based manufacturer of plumbing and fire sprinkler pipe fittings. This straight terminal adapter has a working pressure rating of 175 PSI at 150F (65C) and is suitable for installation in NFPA 13, NFPA 13D, and NFPA 13R systems where allowed by state and local law.

3/4" Slip x 1/2" FNPT CPVC Straight Terminal Adapter is intended for use in light hazard NFPA 13 occupancies, residential NFPA 13R occupancies, and home fire sprinkler systems in accordance with NFPA 13D. This product is UL-listed for use in wet-pipe automatic fire sprinkler systems in combination with UL-listed CPVC products.

3/4" Slip x 1/2" FNPT CPVC Straight Terminal Adapter is backed by Thermafit's ten-year warranty from the date of shipment. Consult Thermafit's installation manual for minimum curing times, compatible adhesives, and friction loss allowances. Not suitable for outdoor installation.

Dimensions

CPVC Straight Terminal Adapter Dimensions

  • A: 1.058"
  • B: 1.046"
  • L: 2.040"
  • M: 1.046" +/- 0.004
  • N: 1.000" +/- 0.004
  • Wall Thickness: 0.396"

Technical Documents

Click here to view the manual for this 3/4" Slip x 1/2" FNPT CPVC Straight Terminal Adapter.

Write Your Own Review
You're reviewing:CPVC Straight Terminal Adapter | 3/4" Slip x 1/2" FNPT Outlet
Your Rating