Handheld Digital Tachometer: Combination Contact and Non-Contact

SKU
CDT2000HD
Checkline CDT 2000 HD Handheld Digital Tachometer provides contact & non-contact measuring from 1 rpm to 99,999 rpm. Accurate to 0.02% with display in rpm, ft/min, in/min, m/sec, & ft/sec. Calibration certificate included.
$321.43
  • Buy 2 for $311.79 each and save 3%
  • Buy 10 for $305.36 each and save 5%
  • Buy 50 for $289.29 each and save 10%
Part NumberOptical Measuring Range (RPM)Mechanical Measuring Range (RPM)Material
CDT2000HD1-99,999 rpm1-99,999 rpmMolded Rubber Shell
ResolutionAccuracyUnitsSensing Distance
.01 from 0 - 100 rpm
.1 from 100 - 1,000 rpm
1 from 1000 - 99,999 rpm
+/- 0.02% of Reading or +/- 1 DigitRPM, FT/MIN, IN/MIN, M/SEC, & FT/SECUp to 24" (60cm)
Battery LifeBattery TypeAvailability
40 Hours Continous Use2 AA BatteriesUsually Ships Within 48 Hours

Product Description

Checkline CDT 2000 HD Handheld Digital Tachometer measures revolutions per minute (RPMs) from as low as 1 to 99,999 (contactless) or 19,999 (contact)! This device is a combination contactless model and a contact model. Traceable calibration certificate provided with each model.

In contactless mode, this Handheld Digital Tachometer uses a visible beam of light that reflects off reflective tape placed on the rotating object. Checkline's contactless mode provides accurate measurements from up to 24" (60.9 cm) away.

In contact mode, the Checkline CDT 2000 HD touches the rotating object with specially designed tips. This tachometer is perfect for machine operators, maintenance professionals, and others in machine operating or material handling roles.

Kit includes:

  • Tachometer
  • Slide-In Contact Adapter
  • 6" & .1m Surface Speed Wheels
  • Cone Tip
  • Funnel Tip
  • Extension Shaft
  • Reflective Tape
  • Two (2) AA Batteries (1.5 V)
  • Calibration Certificate
  • Operating Instruction Manual
  • Foam-fitted, hard-plastic Carrying Case

Product Details

  • Accuracy of 0.02% and a resolution of 0.01 RPM.
  • Built in memory stores maximum, minimum, average, and last reading for recall to display.
  • Molded rubber shell for maximum durability.
  • Includes larger 6" surface speed wheel!

Technical Documents

Click here to view the data sheet for this Checkline CDT 2000 HD Handheld Digital Tachometer.