Fire Extinguisher Sign | Three-Way (6″ x 6″) Pictographs | Glow-in-the-Dark

SKU
L1201
Everlux’s L1201 self-illuminated fire extinguisher sign clearly indicates the location of firefighting equipment. With 180 degrees of visibility, this three-way sign uses two 6″ x 6″ pictographs (symbols), is coated with a photoluminescent pigment, and features white markings on a red base.
$16.95
  • Buy 2 for $16.44 each and save 3%
  • Buy 10 for $16.10 each and save 5%
  • Buy 50 for $15.26 each and save 10%
SKU Construction Finish
L1201 Vinyl Photoluminescent Pigment (White on Red)
Dimensions Listings & Approvals
5 29/32″ x 5 29/32″ (150 mm x 150 mm) Provides Illumination in Accordance with ASTM E2072
Everlux Part No. Availability
L1201 Usually Ships Within 48 Hours

Everlux Three-Way Pictographic Glow-in-the-Dark Fire Extinguisher Sign

The White-on-Red Everlux Photoluminescent Fire Extinguisher Sign glows in the dark and does not require electricity.  Each three-way sign directs occupants to the location of a fire extinguisher using two photoluminescent symbols and backings designed to provide 180 degrees of visibility.

Each of these glow-in-the-dark fire extinguisher signs offers:

  • A minimum of 90 minutes’ illumination
  • Universal pictograms (symbols) representing a fire extinguisher
  • Two 5-29/32" x 5-29/32" (150 mm x 150 mm) sides combined into a single, triangle-shaped sign

Manufactured by Everlux, a world-renowned maker of safety signage, this glow-in-the-dark sign features a photoluminescent body, clear symbols, and high-contrast text. The pigment provides 90 minutes’ illumination after sufficient exposure to light in accordance with ASTM-E2073, ASTM International’s testing standard for photoluminescent markings.

How does this fire extinguisher sign work?

This white-and-red sign (with pictogram) glows after sufficient exposure to light. Note, however, that the “reliable light source” required by life safety codes typically can’t be natural lighting. Every photoluminescent sign needs illumination from an external charging light to glow in accordance with their standards or listings.

This sign will provide a minimum of 5.5 millicandelas per square meter (mcd/m²) when charged—enough light to be seen and understood from over 26 feet away.

Each sign can fully charge in 60 minutes when provided with a light source delivering:

  • 54 lux (or 5 footcandles) of light
  • A cool white source color (4000K)

These required levels of light may be provided by fluorescent and LED lights with a cool white color temperature. These lights are bright and typically reserved for indoor walkways and workspaces. Other types of lighting—even very bright incandescent (traditional) bulbs or neon signs—shouldn’t be used as external charging lights.

Where and how should I install this three-way fire extinguisher sign?

Under NFPA 10: Standard for Portable Fire Extinguishers, fire extinguishers must be installed in high-visibility locations or their positions clearly indicated when visually obstructed. This sign enhances visibility and complies with ASTM E 2072: Standard Specification for Photoluminescent (Phosphorescent) Safety Markings.

This three-way photoluminescent Everlux fire extinguisher emergency sign is designed for surface mounting on a wall. This sign is ideal for buildings with only one floor and can supplement stairwell or door signs that direct users to an extinguisher in a multi-story building.

With this standalone sign, installers can either:

  • Place heavy-duty, double-sided sign tape (or a similar adhesive) on the edge of the sign
  • Use drywall screws or other sign-mounting hardware, mounting along the sign’s border as needed