Viking™ VK430 Pendent Sprinkler | Residential | 4.3K | White | 155F | 09530MB/W-TQ

SKU:
VK430WH155
Manufacturer Part Number:
09530MB/W-TQ
$26.46
Data Sheet Product Data Sheet

Select Variation

  • Buy 50 - 99 and get 3% off
  • Buy 100 or above and get 7% off

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS SKU:
VK430WH155
Manufacturer Part Number:
09530MB/W-TQ
Manufacturer:
Viking™
SIN:
VK430
Model:
Freedom
Head Type:
Pendent
Finish:
White
Finish Detail:
White Polyester
Size:
1/2 in.
Size Detail:
1/2 in. NPT Sprinkler
K Factor:
4.3K
Response Type:
Residential
Temperature:
155F
Heat Element:
Glass Bulb
Coverage:
Standard Coverage
Material:
Brass Frame, Brass Deflector
Corrosion Resistant:
Yes
May Contain Lead:
No
UL Listed:
Yes
FM Approved:
No
Maximum Working Water Pressure:
175 PSI
Escutcheon Type:
Recessed or Surface Mounted
Length:
1.25 in. (31.75 mm)
Width:
1.25 in. (31.75 mm)
Height:
2.25 in. (57.15 mm)
Weight:
0.17 lb. (0.08 kg)
Original Part Number:
09530MB/W
System Type:
Wet
InstaSeal Compatible:
Yes

Viking™ VK430 Pendent Sprinkler | Residential | 4.3K | White | 155F | 09530MB/W | QRFS™ | Hero

Viking™ VK430 Pendent Sprinkler | Residential | 4.3K | White | 155F | 09530MB/W | QRFS™ | Hero
Viking™ VK430 Pendent Sprinkler | Residential | 4.3K | White | 155F | 09530MB/W | QRFS™ | Side
Viking™ VK430 Pendent Sprinkler | Residential | 4.3K | White | 155F | 09530MB/W | QRFS™ | Deflector
Viking™ VK430 Pendent Sprinkler | Residential | 4.3K | White | 155F | 09530MB/W | QRFS™ | Family
Play Button
Overview

Viking™ Freedom Residential Response Pendent (VK430) Fire Sprinkler Head

This Viking™ Freedom Residential Pendent Fire Sprinkler features a glass bulb activating at 155F (68C) with a 4.3 K-Factor, and 1/2 in. NPT threads. Each pendent head features a brass frame and brass deflector. The Sprinkler Identification Number (SIN) is VK430. This is a residential response, standard coverage sprinkler with a maximum working water pressure of 175 PSI.

The VK430 pendent sprinkler delivers effective, affordable defense against fire in residential home sprinkler systems. Using a heat-activated glass bulb assembly, this automatic fire sprinkler opens when ambient temperatures reach 155F (68C), drenching the area surrounding a fire to keep it in its place of origin. For recessed application, refer to data sheet for installation instructions with the approved Viking™ escutcheon(s).

Viking™ Pendent Freedom Fire Sprinkler (VK430) Sprinkler Head Listings and Approvals

Each Freedom residential sprinkler is made by Viking™, a global leader in fire protection manufacturing for nearly 100 years. When installed properly, this fire sprinkler head maintains listings and approvals from cULus (Category VKKW) and is NYC Approved (MEA 89-92-E, Volume 24). Refer to the datasheet for listings and approvals in specific temperatures and/or applications.

When using Viking™ Residential Pendent Sprinkler VK430 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of coverage and minimum water supply requirements shown in the Approval Chart on page 3 of the datasheet (UL). This sidewall sprinkler head has a maximum working pressure of 175 PSI (12.1 BAR) UL and connects to wet piping systems.

Viking™ Freedom (VK430) Pendent Residential Sprinkler Installation and Other Information

During installation be aware that over tightening will cause permanent damage to the 1/2 in. NPT threads and/or the fire sprinklers themselves. Use the manufacturer approved installation wrench and tighten to a maximum torque of 14 ft-lb (19 N-m). Refer to the data sheet for additional storage and installation information.

This residential pendent sprinkler features a white finish and a 155F (68C) temperature. Available finish options include Brass, Chrome, White, and Black. White Polyester Painted (White), and Flat Black Polyester Painted (Black) are UL Listed as corrosion resistant. Temperature options include 155F (68C) and 175F (79C). Finish and temperature combinations available in the “Options” section at the top of this product page.

Reviews
No reviews yet
Product Alternatives