Viking™ VK500 Pendent Sprinkler | FR | InstaSeal | 14.0K | Brass | 165F | 27393AC-TQ

SKU:
VK500BR165-TQ
Manufacturer Part Number:
27393AC-TQ
$31.24
Data Sheet Product Data Sheet

Select Variation

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS SKU:
VK500BR165-TQ
Manufacturer Part Number:
27393AC-TQ
Manufacturer:
Viking™
SIN:
VK500
Model:
ESFR InstaSeal
Head Type:
Pendent
Finish:
Brass
Finish Detail:
Brass
Size:
3/4 in.
Size Detail:
3/4 in. NPT Sprinkler
K Factor:
14.0K
Response Type:
Fast Response (FR)
Temperature:
165F
Heat Element:
Fusible Link
Coverage:
Standard Coverage
Material:
Brass Frame, Brass Deflector
Corrosion Resistant:
No
May Contain Lead:
Yes
UL Listed:
Yes
FM Approved:
Yes
Other Listings:
cULus
Maximum Working Water Pressure:
175 PSI
Sourced Location:
USA
Length:
2.875 in. (73.025 mm)
Width:
1.75 in. (44.45 mm)
Height:
2.875 in. (73.025 mm)
Weight:
0.29 lbs. (0.13 kg)
Carton Quantity:
50
System Type:
Wet
InstaSeal Compatible:
Yes

Viking™ VK500 Pendent Sprinkler | FR | InstaSeal | 14.0K | Brass | 165F | 27393AC-TQ | Hero

Viking™ VK500 Pendent Sprinkler | FR | InstaSeal | 14.0K | Brass | 165F | 27393AC-TQ | Hero
Viking™ VK500 Pendent Sprinkler | FR | InstaSeal | 14.0K | Brass | 165F | 27393AC-TQ | Side
Viking™ VK500 Pendent Sprinkler | FR | InstaSeal | 14.0K | Brass | 165F | 27393AC-TQ | Alt Side
Viking™ VK500 Pendent Sprinkler | FR | InstaSeal | 14.0K | Brass | 165F | 27393AC-TQ | Deflector
Overview

Viking VK500 Pendent (VK500) InstaSeal Fire Sprinkler Head

This Viking FR Pendent Fire Sprinkler features a fusible link activating at 165F (74C) with a 14.0 K-Factor, and 3/4 in. NPT threads. Each pendent head features a brass frame and brass deflector. The Sprinkler Identification Number (SIN) is VK500. This is a standard response, standard coverage sprinkler with a maximum working water pressure of 175 PSI (UL), 175 PSI (FM).
The VK500 pendent sprinkler delivers effective, high-capacity defense against fire in standard hazard occupancies in commercial building sprinkler systems. Using a heat-activated fusible link assembly, this automatic fire sprinkler opens when ambient temperatures reach 165F (74C), drenching the area surrounding a fire to keep it in its place of origin.

Viking FR Pendent Fire Sprinkler VK500 Sprinkler Head Listings and Approvals

Each VK500 pendent sprinkler is made by Viking, a global leader in fire protection manufacturing for nearly 100 years. When installed properly, this fire sprinkler head is UL Listed, FM Approved, and cULus Listed. Refer to the datasheet for listings and approvals in specific temperatures and/or applications.
The sprinkler is UL Listed as indicated in the datasheet for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers.
The sprinkler is FM Approved as a standard response Non–Storage pendent sprinkler as indicated in the FM Approval Guide in the datasheet.

Viking VK500 Pendent Sprinkler Installation and Other Information

During installation be aware that over tightening will cause permanent damage to the 3/4 in. NPT threads and/or the fire sprinklers themselves. Use the manufacturer approved installation wrench and tighten to a maximum torque as specified in the datasheet. Refer to the data sheet for additional storage and installation information.
This pendent sprinkler features a brass finish and a 165F (74C) temperature. Finish and temperature combinations available in the “Options” section at the top of this product page.
The VK500 listed accessories include the approved Viking wrench and the approved Viking escutcheon(s), when applicable. Commonly purchased with fire sprinkler head cabinets and sprinkler shut off tools.

Reviews
No reviews yet
Product Alternatives