Grooved Flange Adapter | GemLock™ | 3 in. | Style F190

SKU:
53-GM-FA-ST-220000
Manufacturer Part Number:
400-210-03103
$56.96

Select Variation

  • Buy 8 - 39 and get 2.5% off
  • Buy 40 or above and get 7.5% off

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS™ SKU:
53-GM-FA-ST-220000
Manufacturer Part Number:
400-210-03103
Manufacturer:
GemLock™
Fitting:
Flange Adapter
Style:
Style F190
Size:
3 in.
Size Detail:
3 in. Grooved
UL Listed:
Yes
FM Approved:
Yes
Rated Working Water Pressure:
300 PSI
Finish:
Orange
Length:
4 in. (101.6 mm)
Weight:
11 lb. (4.99 kg)

Note: Image may not show actual size. | QRFS™

Play Button
Overview

GemLock™ Grooved Flange Adapter

This Grooved Flange Adapter features one 3 in. connection to be used in grooved piping, including specifically fire sprinkler piping systems, allowing for proper water flow and fast installation. This flange adapter nipple is available in the following sizes:

2 in., 2-1/2 in., 3 in., 4 in., 5 in., 6 in., 8 in., 10 in.

You can select your preferred size from the “Options” section at the top of this product page. Accessories compatible with this grooved elbow include other GemLock™ grooved fittings and Pipe Joint Lubricant.

GemLock™ is a leader in the grooved pipe market – their grooved fittings are reliable and faster to install than welding threading, or flanging, resulting in drastically lower installation costs comparatively. GemLock™ grooved fittings provide a clean, consistent, and strong connection for optimal water flow when used with compatible products. The Victaulic™ pipe fitting equivalent to this product is the Victaulic™ Grooved Flange Adapter Style 41. Gruvlok fitting equivalent: 7083P Flange Adapter.

GemLock™ Grooved Flange Adapter Nipples are full flow design, made of durable, high-strength ductile iron conforming to ASTM A536 and conform to Class ANSI 125 lb. flange, with every lot metallurgically tested for compliance. These flange adapters are for use with ductile iron pipe. Pressure Ratings of GemLock™ Grooved Standard fittings are tested to a maximum operating pressure of 300 PSI*.

*Maximum pressure includes surges and maximum end loads from all internal and external forces, to which a joint could be subject under normal working conditions. This rating provides a nominal safety factor of 1.5 times working pressure based on standard weight steel pipe. Maximum working pressure may be subjected to a one-time field test of 1.5 times the figures indicated.

GemLock™ Grooved Flange Adapter Listings, Approvals, and Other Information

Each Flange Adapter is made by GemLock™, a New York-based manufacturer of fire sprinkler grooved pipe fittings, HVAC, plumbing and grooved tubing. All GemLock™ grooved piping system fittings are UL Listed and FM Approved. Refer to installations and groove specifications when assembling any grooved product.

All GemLock™ Ductile Iron fittings conform to ASTM A536 Grade 65-45-12. Allowable pipe end separation is for cut groove pipe for roll groove; figures will be one-half of the values listed at time of initial pressurization.

Certain GemLock™ product families and all GemLock™ Grooved fittings 8 in. and larger are only available upon request and are not available for immediate shipping.